4.2  24 VDC / 48 VDC*

 

power supply 

The device is available with a 24 VDC and a 48 VDC* power supply. 

The power supply is fed in via a 4-pin plug. (The figure shows the socket inside the device). 
 

PIN 

Signal 

 

PE 

0V DC 

IGN 

Nominal 24V:  10…36 VDC 

Nominal 48V*: 18…60 VDC 

 

 

Recommendation for use: 

The power supply must be protected with a 4A fuse (slow-blow). 

 

 

 

ATTENTION

 

Hazard due to overvoltage 

If the protective earth is not attached, there is a 
danger of overvoltage at the device. 

 Always attach the protective earth! 

 

The power supply is realized by means of a transformer. The primary side of the transformer, which is 
connected to mains, is electrically insulated from the secondary side of the transformer, which provides 
the internal power supply. 

Functional EMC protection is provided only if the PE-pin of the power supply is connected to earth. 

When mounting on mobile vehicles, a functional earth must be established for this purpose. 

 

* The UL marking only applies to 24 VDC power supply.  

 

 

Summary of Contents for VMT7000 series

Page 1: ...Instruction manual Terminals VMT7000 series Updated 2018 06 25 Version 2 6 Translation of the original instruction manual...

Page 2: ...on 9 3 2 Damage due to improper use 9 3 3 Warranty repairs 9 3 4 Intended use 9 3 5 Improper use 10 3 6 Treatment and disposal of lithium batteries 10 3 7 Safety instructions 11 4 Product description...

Page 3: ...31 7 1 Front Panel Operation Keys 31 7 2 Soft keyboard 32 7 3 Touch screen 33 7 4 Status displays 34 7 5 Speakers 35 8 Wireless 36 8 1 WLAN optional 36 8 2 RFID reader as an option 38 8 3 RFID config...

Page 4: ...ell as consequential damage that is was the result of non compliance with this instruction manual improper use of the device repairs and other actions on the device by unqualified electricians and ele...

Page 5: ...are identified by an arrow 2 3 Explanation of used symbols DANGER Indicates an imminent danger If not avoided death or severe injury will result WARNING Indicates a possible danger If not avoided dea...

Page 6: ...the best of our knowledge They do not represent any assurance for the properties themselves Despite taking utmost care no liability can be assumed for accuracy completeness and actuality of the inform...

Page 7: ...es including a heater in operation 30 55 C for storage 30 60 C Humidity in operation 10 85 without condensate for storage 10 85 without condensate This unit is compliant to the DIN EN 60068 2 27 shock...

Page 8: ...vironments A corresponding EC conformity declaration is available for competent authorities at the manufacturer and can be viewed upon request The EC conformity declaration can be requested at http ww...

Page 9: ...al and have access to it at all times Assembly commissioning and operation may only be performed by qualified and trained personnel The safety notices and the manual itself must be observed by all per...

Page 10: ...avoid overheating in operation The device must not be exposed to direct radiation by sunlight or any other heat source 3 2 Damage due to improper use Should the control system have evident signs of da...

Page 11: ...ions or due to improper use or handling it must be shut down immediately Ensure that it is secured against being started up accidentally 3 6 Treatment and disposal of lithium batteries This device con...

Page 12: ...be caused by electrostatically sensitive components All installation and service work performed on the device must be performed only under safe secure and de energised conditions Recommendation for u...

Page 13: ...GmbH Heinrich Hertz Str 1 72622 N rtingen Germany 4 Product description 4 1 Device features Front side Fig 1 No Description 1 Display with touch function 2 Front buttons 3 WLAN antennas optional 4 Fr...

Page 14: ...00 series 13 ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen Germany Rear side Fig 2 No Description 6 Service slot 7 Mounting bracket optional 8 Cover for third WLAN antenna 9 Mounting point for bra...

Page 15: ...ENTION Hazard due to overvoltage If the protective earth is not attached there is a danger of overvoltage at the device Always attach the protective earth The power supply is realized by means of a tr...

Page 16: ...nt at the ignition contact Prefabricated supply cables are available from ADS TEC for using the ignition function Recommendation for use Switching the device on or off by using the ON OFF pushbutton w...

Page 17: ...ce slot There are 3 USB connections in the service slot of the device Recommendation for use The total current at each USB interface is limited to 1 A The device supports a maximum of 8 external USB m...

Page 18: ...rk topology must be observed If the drivers necessary for the function are not installed they can be downloaded from the website www ads tec de downloads Pin Signal 1 MDI0 2 MDI0 3 MDI1 4 MDI2 5 MDI2...

Page 19: ...CCMP AES WPA2 TKIP CCMP AES WPA PSK preshared key WPA enterprise EAP TLS The specifications of this network topology must be observed Recommendation for use The device can optionally be equipped with...

Page 20: ...ermany 4 7 Bluetooth wireless card optional The device can optionally be equipped with a Bluetooth wireless module The following Bluetooth standards are available Option Name Range Option 1 Bluetooth...

Page 21: ...ch in the service slot of the device must be put in the ON position in order to use this function A subsequent restart of the computer is required in order to properly activate this function Interface...

Page 22: ...ice series supports various mounting options Further information can be found on our website www ads tec de ATTENTION Hazard due to excessive tightening torque The device can be damaged if the tighten...

Page 23: ...Heinrich Hertz Str 1 72622 N rtingen Germany No Description 1 Bracket for Rittal housing connector top 2 VESA 75 Standard bracket 3 Table vehicle bracket 4 Mounting bracket left right 5 Bracket for R...

Page 24: ...VMT7000 series 23 ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen Germany 5 1 External Device Dimensions VMT7008 Fig 3...

Page 25: ...VMT7000 series 24 ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen Germany 5 2 External Device Dimensions VMT7010 Fig 4...

Page 26: ...VMT7000 series 25 ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen Germany 5 3 External Device Dimensions VMT7012 Fig 5...

Page 27: ...VMT7000 series 26 ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen Germany 5 4 External Device Dimensions VMT7015 Fig 6...

Page 28: ...ocated in the service slot It has to be removed in order to connect the power supply lead and the interface cables All necessary cables must be connected at the beginning of commissioning ATTENTION Ha...

Page 29: ...aching of IP protection The device can be damaged if the service slot cover is not attached or is attached incorrectly Make sure that the service slot cover is attached correctly before starting opera...

Page 30: ...ription 1 X1 PE 0V IGN 24V X1 PE 0V IGN 48V optional DC IN 2 S1 AUTOSTART OFF ON Autostart function 3 X2 WLAN S2 COM 5V OFF ON Preparation for ext WLAN 5V connection at port COM1 4 X3 COM COM1 port RS...

Page 31: ...is provided only if the PE pin of the power supply plug is connected to earth When mounting on mobile vehicles a functional earth must be established for this purpose If the device is to be earthed th...

Page 32: ...The operating system is shut down but the device is not disconnected from the input voltage Level 1 Activate and deactivate the soft keyboard for letter character input by using the touch screen Leve...

Page 33: ...ied in accordance with customer specific requirements The above described functions are pre set ex works Pos 21 D atentechni k Bedienung Softkeyboard Softkeyboar d f r VM T 60xx 1 mod_1228750145198_6...

Page 34: ...ard The Shift Alt and Ctrl special keys must always be pressed first Due to differences in programming of a large variety of software programs we cannot ensure that the soft keyboard works properly wi...

Page 35: ...ig 12 The following signals are displayed System LED indicators Behaviour Description green static Device is connected to a power source and switched on orange fl ashing Volume display brightness is b...

Page 36: ...volume level is modified accordingly If the soft keyboard has been installed the system volume is additionally displayed by a bar graph If the Fn button is touched the backlighting of the buttons cha...

Page 37: ...karte f r VMT 6000 Serie 2 mod_1260517076470_6 doc 6872 8 Wireless 8 1 WLAN optional WLAN antenna emission at front and rear As an option the device can be equipped with a Mini PCI Express WLAN card T...

Page 38: ...s of an R SMA plug This function is optional and must be installed at the factory ATTENTION Hazard due to violation of transmit frequencies Due to the use of non approved antennas If an external anten...

Page 39: ...e available for automatic system login The user applies the RFID tag like a key and requires neither user name nor password For authentication the transponder is raised to the position indicated in th...

Page 40: ...pment a MIFARE or LEGIC RFID reader is installed 8 3 1 MIFARE To test the RFID function select the ADS TEC RFID example application via the pre installed Configuration Center Recommendation for use De...

Page 41: ...d the application opens the interface which is then ready to receive data The data from a transponder are output on the user interface 8 3 2 LEGIC To test the RFID function select a suitable editor No...

Page 42: ...RFID reader or barcode scanner can thereby be automatically directed to the active application without any additional work Fig 16 The functionality of the application can be activated or deactivated a...

Page 43: ...tively be equipped with an SSD Its capacity depends on the desired operating system and the additional programs to be installed Pos 35 D atentechni k Laufwer ke Exter ne Laufwerke Exter ne Laufwer ke...

Page 44: ...drive has been reformatted the operating system can be reinstalled by using one of the existing interfaces An external keyboard is required for installation Installing the operating system The device...

Page 45: ...nt Type of maintenance Maintenance interval BIOS battery Replace AA 3V buffer battery Type FDK Corp CR14250SE ADS TEC part number DZ SONS 04100 0 3 years Fuse Replace 7A 32Vdc Littelfuse INC F200 F120...

Page 46: ...a minimum of 80 GB SATA 2 5 SSD 8 16 32 64 GB Interfaces COM 1 RS232 5V supply can be activated for scanner 1 x USB 2 0 5 in front panel 3 x USB 2 0 5 All external USB interfaces in high current desi...

Page 47: ...such questions ADS TEC does not provide support services for any device that was not purchased directly from ADS TEC In this case maintenance and support is provided by the partner company 13 1 ADS TE...

Reviews: