D
D
Gas system
11
84
Adria Motorhomes
11.6.1
Placing the SecuMotion/MonoControl CS into service
Placing the SecuMotion/MonoControl CS into service:.
Open the shut-off valve (Fig. 58/1) of the full gas cylinder.
Press the reset knob (green button) (Fig. 58/2) on the high-pressure hose (Fig. 58/3)
firmly and hold it depressed briefly.
Hold the gas flow monitor reset knob (green button) (Fig. 58/4) on the gas pressure reg-
ulator (Fig. 58/5) depressed for approx. 5 seconds.
If required, repeat the process.
The gas appliances can now be placed into service.
11.6.2
SecuMotion/MonoControl CS - changing gas cylinders
Use the screwing tool provided for screwing the high-pressure hose on and off.
The screwing tool ensures the required tightening torque and prevents damage to the screw
connection caused by wrong tools.
Important!
If not used for a longer period and with the gas cylinders closed, the SecuMotion/MonoCon-
trol CS can be switched off.
Fig. 58
Truma-SecuMotion/MonoControl CS
1
Shut-off valve of operating cylin-
der
2
Reset knob (green)
3
High-pressure hose
4
Gas flow monitor reset knob
(green)
5
Gas pressure regulator
1
2
3
5
4
Summary of Contents for Motorhome 2012
Page 2: ...D D Contents 2 Adria Motorhomes ...
Page 16: ...D D Placing into service 4 16 Adria Motorhomes ...
Page 22: ...D D During the journey 6 22 Adria Motorhomes ...
Page 88: ...D D Gas system 11 88 Adria Motorhomes ...
Page 110: ...D D Heater hot water 13 110 Adria Motorhomes ...
Page 124: ...D D Refrigerator freezer compartment 15 124 Adria Motorhomes ...
Page 130: ...D D Toilet 16 130 Adria Motorhomes ...
Page 134: ...D D Winter camping 17 134 Adria Motorhomes ...
Page 168: ...D D Troubleshooting 21 168 Adria Motorhomes ...