D
D
Troubleshooting
21
Adria Motorhomes
165
21.9
Power supply faults
Fault
Possible cause
Remedy
Ground-fault circuit
breaker triggers
Fault in 230 V cables of vehi-
cle.
•
Contact Customer Service.
Fault in an electrical appli-
ance.
•
Disconnect all electrical appli-
ances until the ground-fault
circuit breaker no longer trig-
gers.
•
Have defective appliances
repaired by a qualified electri-
cian.
Living area battery is
not charged in 230 V
operation
No mains voltage.
•
Switch on the circuit breaker
in the vehicle.
•
Have the mains voltage
checked.
Transformer/rectifier defec-
tive.
•
Contact Customer Service.
Living area battery is
overcharged in 230 V
operation
Transformer/rectifier defec-
tive.
•
Contact Customer Service.
Living area battery is
not charged in drive
operation
Too many connected appli-
ances.
•
Switch off the appliances, if
possible.
Living area battery is
overcharged in drive
operation
Generator is defective.
•
Have the generator checked.
Regulator defective.
•
Have the regulator checked.
Starter battery is not
charged in 230 V
operation
No mains voltage.
•
Switch on the circuit breaker
in the vehicle.
•
Have the mains voltage
checked.
Transformer/rectifier defec-
tive.
•
Contact Customer Service.
Summary of Contents for Motorhome 2012
Page 2: ...D D Contents 2 Adria Motorhomes ...
Page 16: ...D D Placing into service 4 16 Adria Motorhomes ...
Page 22: ...D D During the journey 6 22 Adria Motorhomes ...
Page 88: ...D D Gas system 11 88 Adria Motorhomes ...
Page 110: ...D D Heater hot water 13 110 Adria Motorhomes ...
Page 124: ...D D Refrigerator freezer compartment 15 124 Adria Motorhomes ...
Page 130: ...D D Toilet 16 130 Adria Motorhomes ...
Page 134: ...D D Winter camping 17 134 Adria Motorhomes ...
Page 168: ...D D Troubleshooting 21 168 Adria Motorhomes ...