5.4.3
Setting the load cells’ signal
S
E
G
N
1
It
is
the
sensitivity
value
of
the
load
cell.
The
maximum
allowed
signal
is
3.5
mV/V.
5.4.4
Setting the weighing system capacity
P
O
R
T
1
It
is
the
capacity
of
the
weighing system.
The
maximum
capacity
consists
of
100000
divisions.
5.4.5
Setting the system resolution
S
E
N
S
1
The
value
can
be
selected
within
the
range
from
50
to
0.001
divisions.
The
system
resolution
is
given
by
the
ratio
between
capacity
and
resolution.
See
also
point
2.2.1
5.4.6 Average
settings
M
E
D
I
E
1
This
parameter
is
used
for
the
digital
filtering
of
the
weight
signal,
in
order
to
reduce
the
unwanted
effects
due
for
example
to
mechanical
vibrations
that
act
on
the
weighing
system.
The
higher
is
the
parameter’s
value,
the
greater
is
the
ability
to
filter
unwanted
oscillations,
even
if
there
is
a
longer
delay
in
visualizing
the
variations
of
the
weight
signal.
See
point
2.2.4.
OFF
2
4
8
16
32
64
FIR 1
FIR 2
FIR 3
FIR 4
FIR 5