14
Introduction
PCI-9524
ADLINK Technology Inc.
User’s Manual
Copyright 2008
Table 1-11:
Settling Error: (Typical, 25ºC)
X
Time-base source: Internal 40 MHz
X
Trigger mode: post-trigger
X
Offset error:
Z
Before calibration: ±2 mV typical 25ºC
Z
After calibration: ±0.1 mV typical 25ºC
X
Gain error:
Z
Before calibration: ±0.5% typical 25ºC
Z
After calibration: ±0.01% typical 25ºC
Input Range
Condition
Settling Error
±10V
Scanning 20Vpp
<0.0005%
±5V
Scanning 10Vpp
<0.0005%
±2.5V
Scanning 5Vpp
<0.0005%
±1.25V
Scanning 2.5Vpp
<0.0005%