8254 Timer Chip Operation
•
53
Control Byte
Before loading or reading any of these individual counters, the
control byte (BASE+3) must be loaded first. The format of the control
byte is :
Bit
7
6
5
4
3
2
1
0
SC1
SC0
RL1
RL0
M2
M1
M0
BCD
•
SC1 & SC0 - Select Counter ( Bit 7 & Bit 6)
SC1
SC0
COUNTER
0
0
Select Counter 0
0
1
Select Counter 1
1
0
Select Counter 2
1
1
ILLEGAL
•
RL1 & RL0 - Select Read/Load operation ( Bit 5 & Bit 4)
RL1
RL0
OPERATION
0
0
COUNTER LATCH FOR STABLE READ
0
1
READ/LOAD LSB ONLY
1
0
READ/LOAD MSB ONLY
1
1
READ/LOAD LSB FIRST, THEN MSB
•
M2, M1 & M0 - Select Operating Mode ( Bit 3, Bit 2, & Bit 1)
M2
M1
M0
MODE
0
0
0
0
0
0
1
1
x
1
0
2
x
1
1
3
1
0
0
4
1
0
1
5
•
BCD - Select Binary/BCD Counting ( Bit 0)
0
16-BITS BINARY COUNTER
1
BINARY CODED DECIMAL (BCD) COUNTER (4
DIGITAL)
Note
The count of the binary counter is from 0 up to
65,535 and the count of the BCD counter is from
0 up to 9,999