48
Operation Theory
Figure 4-28: Inside-Region analog trigger condition
High-Hysteresis analog trigger condition
Figure 4-29 shows the high-hysteresis analog trigger condition,
the trigger signal asserts when the input analog signal level is
higher than the High_Threshold voltage, where the hysteresis
region is determined by the Low_Threshold voltage.
Figure 4-29: High-Hysteresis analog trigger condition
Low-Hysteresis analog trigger condition
Figure 4-30 shows the low-hysteresis analog trigger condition,
the trigger signal asserts when the input analog signal level is
lower than the Low_Threshold voltage, where the hysteresis
region is determined by the High_Threshold voltage.