PRELIMINARY
96
Digital Input/Output Function Library
Return codes
NoError
DI_ReadPort
Reads digital data from the specified digital input port.
Syntax
C/C++ and Borland C++
I16 DI_ReadPort (U32 *Value)
Visual Basic
DI_ReadPort (Value As Long) As Integer
Parameter(s)
Value
Returns the digital data read from the specified port
Valid values include MXC-6400 16-bit data
Return codes
NoError
CardNotRegistered
ErrorInvalidCardNumber
ErrorCardNotRegistered
ErrorFuncNotSupport
DO_WritePort
Writes digital data to the specified digital output port.
Syntax
C/C++ and Borland C++
I16 DO_WritePort (U32 Value)
Visual Basic
DO_WritePort (ByVal Value As Long) As Integer
Parameter(s)
Value
Digital datawritten to the specified port
Valid values include: MXC-6400 16-bit data
Summary of Contents for MXC-6401D
Page 10: ...P R E L I M I N A R Y x Table of Contents This page intentionally left blank ...
Page 12: ...P R E L I M I N A R Y xii List of Tables This page intentionally left blank ...
Page 14: ...P R E L I M I N A R Y xiv List of Figures This page intentionally left blank ...
Page 22: ...P R E L I M I N A R Y 8 Introduction Figure 1 4 MXC 6400 Front View 200 ...
Page 56: ...P R E L I M I N A R Y 42 Getting Started 2 Withdraw one or both of the SATA trays ...
Page 58: ...P R E L I M I N A R Y 44 Getting Started ...
Page 63: ...P R E L I M I N A R Y Getting Started 49 MXC 6400 ...
Page 102: ...P R E L I M I N A R Y 88 Activating RAID Function This page intentionally left blank ...
Page 122: ...P R E L I M I N A R Y 108 Important Safety Instructions This page intentionally left blank ...