14
Introduction
Leading
EDGE COMPUTING
Since the EMX-100 will restart during the reset process, close the
application software on the PC side, or unplug the network cable,
and wait until the Error indicator lights before resetting.
Once the Error indicator is lit:
1. Press and hold the Reset button for 5 seconds. when
Error indicator extinguishes, the EMX-100 has begun to
restart.
2. Press and hold the Reset button for 14 seconds until the
Error indicator extinguishes and release. The EMX-100
sets the IP to the default (192.168.0.1), parameter set-
tings for each axis also return to default values, and the
controller is automatically restarted. Wait for 14 seconds
until the Error indicator lights, indicating that reset is
complete.
1.11 Status LEDs
Two LED indicators on the front panel show device status as fol-
lows.
The Error indicator is also used in software updates. Please refer
to the Appendix for more details.
1.12 Power I/F Circuit
Located inside the power input point of the power connector. the
circuit contains an isolated power converter and overvoltage, over-
current, and reverse protection. A fuse (3.15A/250V) is also avail-
able for replacement in the overcurrent section.
LED
Color
Status
Power
Red
Power on
Error
Yellow
Cable signal interrupted or emergency
stop executed
Summary of Contents for EMX-100
Page 6: ...vi Preface Leading EDGE COMPUTING This page intentionally left blank...
Page 10: ...x List of Figures Leading EDGE COMPUTING This page intentionally left blank...
Page 17: ...Introduction 7 EMX 100 Figure 1 2 Left Side View A Barcode label B MAC address label A B...
Page 38: ...28 Getting Started Leading EDGE COMPUTING This page intentionally left blank...
Page 54: ...44 Important Safety Instructions Leading EDGE COMPUTING This page intentionally left blank...