2.10
Power Specifications
¾
Power Modes:
AT and ATX mode (AT mode start controlled by SEMA)
¾
Standard Voltage Input: ATX = 12V±5% / 5Vsb ±5% or AT = 12V ±5%
¾
Wide Voltage Input: ATX = 8.5~20 V / 5Vsb ±5% or AT = 8.5 ~20V
¾
Power Management: ACPI 4.0 compliant, Smart Battery support
¾
Power States: supports C1-C6, S0, S1, S4, S3, S5, S5 ECO mode (Wake on USB S3/S4, WOL S3/S4/S5)
2.11
Operating Temperatures
¾
Standard Operating Temperature: 0°C to 60°C (wide voltage input)
¾
Extreme Rugged Operating Temperature: -40°C to 85°C (standard voltage input)
2.12
Environmental
¾
Humidity: 5-90% RH operating, non-condensing
5-95% RH storage (and operating with conformal coating).
¾
Shock and Vibration: IEC 60068-2-64 and IEC-60068-2-27
MIL-STD-202F,
Method
213B,
Table
213-I,
Condition A and Method 214A, Table 214-I, Condition D
¾
Halt:
Thermal Stress, Vibration Stress, Thermal Shock and Combined Test
2.13
Specification Compliance
¾
PICMG COM.0: Rev 2.1 Type 6, basic size 125 x 95
2.14
Operating Systems
¾
Standard Support:
Windows 7/8 32/64-bit, Linux 32/64-bit
¾