Item
Sensor Name
Sensor Address
Description
Upper Non-Critical Threshold = 5.3 Volts
Lower Non-Critical Threshold = 4.7 Volts
Lower Critical Threshold = 4.6 Volts
Lower Non-Recoverable Threshold = 4.5 Volts
(13)
DDR3 VTT +0.75V
(0xC)
Voltage Sensor
Upper Non-Recoverable Threshold = 0.83 Volts
Upper Critical Threshold = 0.81 Volts
Upper Non-Critical Threshold = 0.79 Volts
Lower Non-Critical Threshold = 0.71 Volts
Lower Critical Threshold = 0.69 Volts
Lower Non-Recoverable Threshold = 0.67 Volts
(14)
LMP P2041 +1V
(0xD)
Voltage Sensor
Upper Non-Recoverable Threshold = 1.1 Volts
Upper Non-Critical Threshold = 1.08 Volts
Upper Critical Threshold = 1.06 Volts
Lower Critical Threshold = 0.94 Volts
Lower Non-Critical Threshold = 0.92 Volts
Lower Non-Recoverable Threshold = 0.9 Volts
(15)
VDD +1.2V
(0xE)
Voltage Sensor
Upper Non-Recoverable Threshold = 1.32 Volts
Upper Critical Threshold = 1.3 Volts
Upper Non-Critical Threshold = 1.28 Volts
Lower Non-Critical Threshold = 1.13 Volts
Lower Critical Threshold = 1.1 Volts
Lower Non-Recoverable Threshold = 1.08 Volts
(16)
IPMC +1.6V
(0xF)
Voltage Sensor
Upper Non-Recoverable Threshold = 1.76 Volts
Upper Critical Threshold = 1.73 Volts
Upper Non-Critical Threshold = 1.69 Volts
Lower Non-Critical Threshold = 1.5 Volts
Lower Critical Threshold = 1.47 Volts
Lower Non-Recoverable Threshold = 1.44 Volts
(17)
48V Current(A)
(0x10)
Current Sensor
Upper Non-Recoverable Threshold = 9 Amps
(18)
48V_A Power(V)
(0x11)
Voltage Sensor
Upper Non-Recoverable Threshold = 72 Volts
Upper Critical Threshold = 64 Volts
Upper Non-Critical Threshold = 55 Volts
Lower Non-Critical Threshold = 43 Volts
Lower Critical Threshold = 41 Volts
Lower Non-Recoverable Threshold = 39 Volts
(19)
48V_B Power(V)
(0x12)
Voltage Sensor
Upper Non-Recoverable Threshold = 72 Volts