Installation
•
9
ON
1
2
3
4
5
6
A ( 8 7 6 5 4 3 )
SW1
BASE_ADDR. = Hex 300
Figure 2.2 Default Base Address Setting
I/O port
Address(Hex)
1
A8
2
A7
3
A6
4
A5
5
A4
6
A3
200-207
ON
(0)
ON
(0)
ON
(0)
ON
(0)
ON
(0)
ON
(0)
208-20F
ON
(0)
ON
(0)
ON
(0)
ON
(0)
ON
(0)
OFF
(1)
210-217
ON
(0)
ON
(0)
ON
(0)
ON
(0)
OFF
(1)
ON
(0)
218-21F
ON
(0)
ON
(0)
ON
(0)
ON
(0)
OFF
(1)
OFF
(1)
:
:
:
:
:
:
:
2F8-2FF
ON
(0)
OFF
(1)
OFF
(1)
OFF
(1)
OFF
(1)
OFF
(1)
300-307
(default)
OFF
(1)
ON
(0)
ON
(o)
ON
(0)
ON
(0)
ON
(0)
308-30F
OFF
(1)
ON
(0)
ON
(0)
ON
(0)
ON
(0)
OFF
(1)
:
:
:
:
:
:
:
3F0-3F7
OFF
(1)
OFF
(1)
OFF
(1)
OFF
(1)
OFF
(1)
ON
(0)
3F8-3FF
OFF
(1)
OFF
(1)
OFF
(1)
OFF
(1)
OFF
(1)
OFF
(1)
* A3, ..., A8 is corresponding to PC Bus address lines
Table 2.1 Possible Base Address Combinations