Page 5
Electrical requirements (cont.)
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:-
1.
The wire coloured green and yellow
must be connected to the
terminal in the plug that is marked by the letter E, or by the
safety earth symbol coloured green, or green and yellow.
2.
The wire coloured blue
must be connected to the terminal,
which is marked with the letter N, or coloured black.
3.
The wire coloured brown
must be connected to the terminal,
which is marked with the letter L, or coloured red.
NOTE:
Replacement of the mains cable
must be done by a competent service
engineer.
HEATING ELEMENT
The heating element
fitted to the
Studio Plate Press
is rated at 250
Watts.
Never connect
to any outlet or power supply having a different
voltage/frequency from that on the machine data plate.
2.4
Adjusting the pressure
This press is fitted
with a pressure-adjusting table, which enables the
table plate assembly to be raised or lowered.
a)
To increase pressure
or to use thinner materials turn table
anti-clockwise.
b)
To decrease pressure
or to lower the table plate assembly to
enable thicker materials to be used, turn the table clockwise.
NOTE
DO NOT adjust the pressure when the machine is clamped shut
CAUTION
Never increase the pressure to the extent of requiring undue force,
as this will place excessive stress on the press frame, resulting in
permanent damage to the press. If, on raising the handle, the
machine is lifted off the work surface then the clamping force is
excessive!
Please refer to page 11 showing the operation of the control unit.