Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

X-Scan LED.™ The American DJ

®

 X-Scan LED

 is available in a 120v 

and 220v version. Because line voltage may vary from venue to venue, 
you should be sure your unit voltage matches the wall outlet voltage 

before attempting to operate you fixture.  Also be sure to only use the 

included I.E.C. power cable supplied with the unit, this cable matches 
the voltage and current requirements of the unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 
communication  between  intelligent  fixtures  and  controllers. 

A  DMX 

controller sends DMX data instructions from the controller to the fix

-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX  Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of  different  manufactures  to  be  linked  together  and  operate  from  a 

single  controller,  as  long  as  all  fixtures  and  the  controller  are  DMX 

compliant.

  To  ensure  proper  DMX  data  transmission,  when  using 

several DMX fixtures try to use the shortest cable path possible. The 
order in which fixtures are connected in a DMX line does not influence 
the DMX addressing. For example; a fixture assigned a DMX address 
of 1 may be placed anywhere in a DMX line, at the beginning, at the 
end, or anywhere in the middle. Therefore, the first fixture controlled 
by the controller could be the last fixture in the chain. When a fixture 
is  assigned  a  DMX  address  of  1,  the  DMX  controller  knows  to  send 
DATA assigned to address 1 to that unit, no matter where it is located 
in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX 

and Master/Slave Operation): 

The X-Scan LED™ 

can  be  controlled  via  DMX-512  protocol.  The  X-
Scan LED™ is be a eight channel DMX unit. The 
DMX  address  is  set  electronically  using  the  con-
trols  on  the  rear  panel  of  the  unit.  Your  unit  and 
your DMX controller require a approved DMX-512 
110 Ohm Data cable for data input and data output 
(Figure 1). We recommend Accu-Cable DMX cables. If you are making 

 X-Scan LED™ 

 

                                           Set Up

Figure 1

your own cables, be sure to use standard 110-120 Ohm shielded cable 
(This  cable  may  be  purchased  at  almost  all  professional  sound  and 
lighting stores). Your cables should be made with a male and female 
XLR connector on either end of the cable. Also remember that DMX 
cable must be daisy chained and cannot be split.

 X-Scan LED™ 

 

 

 

                       Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Summary of Contents for X-SCAN LED PLUS

Page 1: ...r dealer without contacting customer support first Introduction The X Scan LED is a eight channel DMX intelligent LED scanner The X Scan LED can operate as a stand alone fixture or in a Master Slave c...

Page 2: ...d has been spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance X Scan LED Safety...

Page 3: ...s set electronically using the con trols on the rear panel of the unit Your unit and your DMX controller require a approved DMX 512 110 Ohm Data cable for data input and data output Figure 1 We recomm...

Page 4: ...a 3 pin DMX line When inserting stan dard 5 pin data cables in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a prope...

Page 5: ...OFF Press the UP or DOWN buttons to select ON to activate sound active mode or OFF to deactivate sound active mode 3 Press ENTER to confirm BLND Blackout or Stand by mode 1 Tap the MENU button until B...

Page 6: ...n the slave units tap the MENU button until SLMD is dis played and Press ENTER 4 The slave units will now follow the Master unit Universal DMX Control This function allows you to use a Elation univers...

Page 7: ...ional UC3 Controller not included may be used to con trol different functions including blackout X Scan LED UC3 Control The optional UC3 Controller not included may be used to con trol different funct...

Page 8: ...rush to wipe down the cooling vents and fan grill 3 Clean the external optics and mirror with glass cleaner and a soft cloth every 20 days 4 Clean the internal optics with glass cleaner and a soft clo...

Page 9: ...e and repair labor by reason of defects in material or workmanship The sole responsibility of American DJ Inc under this warranty shall be limited to the repair of the product or replace ment thereof...

Page 10: ...om Model X Scan LED Voltage 100 240V 50Hz 60Hz Auto Sensing LEDs 1 X 20 Watt LED Power Consumption 44W Dimensions 8 L x 6 W x 15 25 H 200mm x 150mm x 386mm Colors RGB White Weight 9 9 Lbs 4 5 kgs Fuse...

Reviews: