ADJ WiFLY EXR HEX5 IP User Manual Download Page 26

26

CLEANING

Due to fog residue, smoke, and dust, cleaning the internal and external optical lenses must be car-

ried out periodically to optimize light output. 

•  Use normal glass cleaner and a soft cloth to wipe down the outside casing.

•  Periodically clean the external optics with glass cleaner and a soft cloth.

•  Always be sure to dry all parts completely before plugging the unit back in.

Cleaning frequency depends on the environment in which the fixture operates (i.e. smoke, fog resi-

due, dust, dew).

POWER CORD DAISY CHAIN

These units have the capability to be daisy chained together via the power in/out ports. The maxi-

mum number of units that can be linked together in this manner is 10 units.

DO NOT EXCEED THE NUMBER OF UNITS LISTED ABOVE.

DO NOT MIX MAKE AND MODEL TYPES WHEN DAISY CHAINING! All units that are connected in 

this manner must be of the same make and model type.

Note: Fixtures cannot be daisy chained while running on battery power.

TROUBLE SHOOTING

Listed below is a common problem the user may encounter, with a possible solution.

Unit not responding to DMX:

Check that the DMX cables are connected and wired correctly (pin 3 is “hot”; on some other DMX 

devices pin 2 may be “hot”). Also, check that all cables are connected to the right connectors, as the 

order in which the inputs and outputs are connected does affect how the unit operates. 

Summary of Contents for WiFLY EXR HEX5 IP

Page 1: ...User Manual WIFLY EXR HEX5 IP...

Page 2: ...injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficie...

Page 3: ...Battery Precautions 9 Setup 11 Operating Instructions 14 Primary Secondary Configuration Wifly Setup 18 ADJ RFC Operation 19 DMX Traits 20 Color Macros Chart 23 Battery Status and Charging Photometri...

Page 4: ...tery will keep charge for up to 5 hours full on from a full single charge or 7 hours in energy saving mode This fixture can be used in a stand alone mode or connected in a Primary Secondary configurat...

Page 5: ...e written down on a piece of paper included in the shipping carton If the unit is under warranty you must provide a copy of your proof of purchase invoice You may obtain an R A number by contacting ou...

Page 6: ...ich the cords exit from the unit Cleaning The fixture should be cleaned only as recommended by t he manufacturer See the Cleaning section of this manual for details Heat The appliance should be situat...

Page 7: ...high pressure water jets from any direction 5 MARINE COASTAL ENVIRONMENT INSTALLATIONS Please note that although this fixture is IP rated the fixture is NOT suitable for marine and or coastal environ...

Page 8: ...tdoor wet environment with out usage as stated above can lead to component damage and or shortening the lifetime of the fixture Any component damage that has been determined to be the direct result of...

Page 9: ...such a way as to prevent short circuits that can result in smoke or fire 2 3 Do not disassemble the batteries Never disassemble the batteries as doing so may result in an internal short circuit in th...

Page 10: ...ork battery performance will deteriorate over time even if stored for a long period of time without being used In addition if various usage condi tions such as charge discharge ambient temperature etc...

Page 11: ...5 IP can be controlled via DMX 512 protocol The WiFly EXR HEX5 IP has 5 DMX channel modes see the DMX Traits section of this manual for detailed information The DMX address is set on the back panel of...

Page 12: ...terminator ADJ part number Z DMX T will decrease the risk of erratic behavior 5 Pin XLR DMX Connectors Some manufactures use 5 pin DMX 512 data cables for DATA trans mission in place of 3 pin 5 pin DM...

Page 13: ...e same DMX address will cause all those fixtures to react in the same way In this case please note that changing the settings of one channel will affect all the fixtures simultaneously If you set each...

Page 14: ...ess the UP or DOWN button so that ON is displayed If ON is displayed already this means that the fixture is already in energy saving mode LED Display On Off To set the LED display light to turn off af...

Page 15: ...UP and DOWN buttons to find your desired color change mode 3 Press the SET UP button and SPEED XX will be displayed Use the UP and DOWN buttons to adjust the speed of the color change Color Fade Mode...

Page 16: ...ing battery life If BATT LEV is displayed it means either the battery is dead or the unit is running on AC power Battery Load This is used to turn the PCB On when the battery is being used 1 Press the...

Page 17: ...return to when power is applied 1 Plug the fixture in and press the MODE button until DMX MODE ADDR XXX is displayed 2 Press the SET UP button until DMX MODE NO XXXX is displayed where XXXX represent...

Page 18: ...is displayed The unit is now set as the Secondary unit Each secondary unit must be set to the same set ting 4 Connect the first Secondary unit to the Primary The Secondary unit should now start to fo...

Page 19: ...will switch between static color mode and second ary mode Use the or to scroll through the 63 static colors Once you have found the desired color you can press the FLASH button to activate strobing a...

Page 20: ...bing slow to fast 160 191 LED On 192 223 Random Strobing slow to fast 224 255 LED On 9 9 Program Selection Mode 000 051 Dimming Mode 052 102 Color Macro Mode 103 153 Color Change Mode 154 204 Color Fa...

Page 21: ...63 Color Fade 4 064 079 Color Fade 5 080 095 Color Fade 6 096 111 Color Fade 7 112 127 Color Fade 8 128 143 Color Fade 9 144 159 Color Fade 10 160 175 Color Fade 11 176 191 Color Fade 12 192 207 Color...

Page 22: ...8 will control strobing When Channel 9 is between the values of 103 153 Channel 10 is in Color Change Mode and Channel 11 will control the color change speed When Channel 9 is between the values of 1...

Page 23: ...115 R B UV 116 119 R W A 120 123 R W UV 124 127 R A UV DMX VALUES COLOR 128 131 G B W 132 135 G B A 136 139 G B UV 140 143 G W A 144 147 G W UV 148 151 G A UV 152 155 B W A 156 159 B W UV 160 163 B A...

Page 24: ...ay BATTERY RECHARGING To recharge the battery plug one end of the supplied AC cord into the AC input on the side of the unit and the other end into a matching power supply It takes approximately 5 hou...

Page 25: ...0 0 1 0 0 1 0 0 5 0 5 0 5 0 5 0 0 0 0 0 1 0 1 0 1 0 1 0 Trise Tdow n t t t t m s m s m s m s Dimmer Dimmer Dimmer Dimmer Delay mode DMX delay Trise ms Tdown ms dr 0 0 0 dr 1 800 1300 dr 2 1010 1560 d...

Page 26: ...ther via the power in out ports The maxi mum number of units that can be linked together in this manner is 10 units DO NOT EXCEED THE NUMBER OF UNITS LISTED ABOVE DO NOT MIX MAKE AND MODEL TYPES WHEN...

Page 27: ...arranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replac...

Page 28: ...nd 12 channel mode Warranty 2 Years 730 days Limited Warranty Battery Lifetime depends on charging frequency See Limited Warranty section of this manual for details Auto Sensing Voltage This fixture c...

Page 29: ...29...