5. Press ENTER to confirm your selection or press MODE to exit.

Tilt Invert

 - With this function you can reverse the left head Tilt 

movement. This function is used with DMX mode.
1. Press the MODE button to access the main menu. Press the UP or 

DOWN buttons so that 

“Function”

 is highlighted, then press ENTER. 

2. Press the LEFT or RIGHT buttons until 

“Status”

 is displayed, press 

ENTER.
3. Press LEFT or RIGHT buttons, until 

“Tilt Invert”

 is displayed, and 

press ENTER. 
4. Either 

“Off”

 or 

“On”

 will be displayed, use the LEFT or RIGHT but-

tons to toggle between.
5. Press ENTER to confirm your selection or press MODE to exit.

Pan Degree

 - With this function you can change the pan degree from 

630 to 540. This function is used with DMX mode.
1. Press the MODE button to access the main menu. Press the UP or 

DOWN buttons so that 

“Function”

 is highlighted, then press ENTER. 

2. Press the LEFT or RIGHT buttons until 

“Status”

 is displayed, press 

ENTER.
3. Press LEFT or RIGHT buttons, until 

“Pan Degree”

 is displayed, 

and press ENTER. 
4. Either 

“540”

 or 

“630”

 will be displayed, use the LEFT or RIGHT 

buttons to toggle between.
5. Press ENTER to confirm your selection or press MODE to exit.

Feedback

 - With this function, you have the pan and tilt postion 

feedback while out of step or not feedback while out of step.
1. Press the MODE button to access the main menu. Press the UP or 

DOWN buttons so that 

“Function”

 is highlighted, then press ENTER. 

2. Press the LEFT or RIGHT buttons until 

“Status”

 is displayed, press 

ENTER.

  Vizi Q Wash7 

                                          System Menu

  Vizi Q Wash7 

                                          System Menu

the address that is currently assingned to the unit. Then set 

Channel 1’s value to “7”, Channel 2’s value to “7”, and Chan-

nel 3’s value to “57”. Wait 20 seconds and the address should 

change on the unit to “57”.

2nd EXAMPLE:

 If you want the address to be 420, you must 

first set the address that is currently assingned to the unit. If 

you want the set the address to 420, set Channel 1’s value to 

“7”, Channel 2’s value to “8”, and Channel 3’s to “164”. (256 + 

164 = 420).

No DMX Mode

 - With this function if the DMX signal is suddenly lost, 

the unit will automatically go into 1 of 3 modes.
1. Press the MODE button to access the main menu. Press the UP or 

DOWN buttons so that 

“Function”

 is highlighted, then press ENTER. 

2. Press the LEFT or RIGHT buttons until 

“Status”

 is displayed, press 

ENTER.
3. Press LEFT or RIGHT buttons, until 

“No DMX Mode”

 is displayed, 

and press ENTER. 
4. Either 

“Hold”

 (Last DMX setting), 

“Blackout”, 

or 

“Auto”

 (Auto 

Program) will be displayed, use the LEFT or RIGHT buttons to toggle 

between.
5. Press ENTER to confirm your selection or press MODE to exit.

Pan Invert

 - With this function you can reverse the Pan movement.

1. Press the MODE button to access the main menu. Press the UP or 

DOWN buttons so that 

“Function”

 is highlighted, then press ENTER. 

This function is used with DMX mode.
2. Press the LEFT or RIGHT buttons until 

“Status”

 is displayed, press 

ENTER.

3. Press LEFT or RIGHT buttons, until 

“Pan Invert”

 is displayed, and 

press ENTER. 
4. Either 

“Off”

 or 

“On”

 will be displayed, use the LEFT or RIGHT but-

tons to toggle between.

Summary of Contents for Vizi Q Wash7

Page 1: ...nds and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipmen...

Page 2: ...to enhance the beams projec tions Customer Support ADJ Products LLC provides a toll free cus tomer support line to provide help and to answer any question should you encounter problems during your se...

Page 3: ...nce does not appear to operate normally or exhibits a marked change in performance Vizi Q Wash7 Safety Precautions ADJ Products LLC www adj com Vizi Q Wash7 Instruction Manual Page 4 DMX 512 Protocol...

Page 4: ...ting removing or servicing the unit Overhead mounting requires extensive experience including calculat ing working load limits installation material being used and perodic safety inspection of all ins...

Page 5: ...s serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a DATA OUT terminal DMX Linking DMX is a language a...

Page 6: ...round Special Note Line Termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behavior A terminator is a 110 120 ohm 1 4 watt resistor which...

Page 7: ...r 3 Use the controller s faders to control the various DMX fixture traits 4 This will allow you to create your own programs 5 Follow the directions on page 24 to select your DMX Channel mode and to se...

Page 8: ...RAM 13 251 255 PROGRAM 14 13 PROGRAM SPEED 0 255 SLOW FAST 14 AUTO PROGRAM FADE 0 NORMAL 0 255 SLOW FAST 15 DIMMER MODE 0 20 STANDARD 21 40 STAGE 41 60 TV 61 80 ARCHITECTURAL 81 100 THEATRE 101 255 DE...

Page 9: ...OBE PULSE SLOW FAST 160 191 LED ON 192 223 RANDOM STROBE SLOW FAST 224 255 LED ON 11 MASTER DIMMER 0 255 0 100 12 DIMMER FINE 0 255 0 100 13 FOCUS 0 255 NEAR FAR Vizi Q Wash7 19 Channel DMX Mode Stand...

Page 10: ...Mode Extend Channel Value Function 1 0 255 PAN MOVEMENT 8bit 540 or 630 2 0 255 PAN MOVEMENT FINE 16bit 3 0 255 TILT MOVEMENT 8bit 4 0 255 TILT MOVEMENT FINE 16bit 5 0 255 RED CENTER LED 0 100 6 0 255...

Page 11: ...RAM 13 251 255 PROGRAM 14 19 PROGRAM SPEED 0 255 SLOW FAST 20 AUTO PROGRAM FADE 0 NORMAL 0 255 SLOW FAST 21 DIMMER MODE 0 20 STANDARD 21 40 STAGE 41 60 TV 61 80 ARCHITECTURAL 81 100 THEATRE 101 255 DE...

Page 12: ...ED GREEN BLUE WHITE RED GREEN BLUE WHITE OFF 0 0 0 0 0 Color33 129 132 255 206 143 0 Color1 1 4 80 255 234 80 Color34 133 136 254 177 153 0 Color2 5 8 80 255 164 80 Color35 137 140 254 192 138 0 Color...

Page 13: ...T or RIGHT buttons to scroll through the 3 DMX Chan nel Modes Standard Mode This is 19 Channel Mode Basic Mode This is 17 Channel Mode Extended Mode This is 23 Channel Mode User Mode A B C These are c...

Page 14: ...buttons so that Function is highlighted then press ENTER 2 Press the LEFT or RIGHT buttons until Status is displayed press ENTER Vizi Q Wash7 System Menu Vizi Q Wash7 System Menu the address that is...

Page 15: ...current stand by setting will be displayed use the LEFT or RIGHT buttons to adjust the hibernation period between 01M 99M or Off 5 Press ENTER to confirm your selection or press MODE to exit Vizi Q W...

Page 16: ...LED See page 44 for the Dimmer Curve Chart 1 Press the MODE button to access the main menu Press the UP or DOWN buttons so that Function is highlighted then press ENTER Vizi Q Wash7 System Menu that F...

Page 17: ...ctivate WiFly and set the wireless address This address must match the address that is set to WiFly TransCeiver Vizi Q Wash7 System Menu or WiFly controller 1 Plug the fixture in and access the main m...

Page 18: ...Vizi Q Wash7 System Menu Auto Pro This function allows the internal programs to run in either stand alone or master slave mode In Master mode the fixture will send DMX data to other fixtures connect...

Page 19: ...IGHT but tons to toggle between 5 Press ENTER to confirm or press MODE to exit Temp Info This will allow you to check the moving head tempera ture 1 Press the MODE button to access the main menu Press...

Page 20: ...Wash7 features an integrated DMX recorder Preprogrammed scenes can be transmitted to the fixture via any DMX compliant controller This function allows those scenes to be stored in to the fixture s bu...

Page 21: ...n menu and press the UP or DOWN buttons so that Function is highlighted then press ENTER 7 Press the UP or DOWN buttons until Disp Set is displayed and press ENTER Vizi Q Wash7 Operation Vizi Q Wash7...

Page 22: ...6020 14000 1718 3410 484 4002 9387 Field angle 10 0 0 1 3 5 8 10 1 1 2 2 3 4 Beam opening m 3 4 7 0 23 0 11 0 31 0 41 0 51 7 Diameter m 10 0 37 0 17 0 53 0 73 0 90 10 Diameter m Vizi Q Wash7 Photomet...

Page 23: ...ns No light output from the unit 1 Be sure the external fuse has not blown The fuse is located on the back panel of the unit next to the PowerCON input connec tion 2 Be sure the fuse holder is complet...

Page 24: ...hout any obligation to include these changes in any products theretofore manufactured No warranty whether expressed or implied is given or made with respect to any accessory supplied with products des...

Reviews: