ADJ Vizi Hybrid 16RX User Instructions Download Page 20

ADJ Products, LLC  -  www.adj.com  - Vizi Hybrid 16RX Instruction Manual Page 38

ADJ Products, LLC  -  www.adj.com  - Vizi Hybrid 16RX Instruction Manual Page 39

  Vizi Hybrid 16RX                                            Lamp Replacement

Replacing the lamp is 

relatively easy. Unplug the 

unit from its power source. 

Allow the unit 15 minutes 

to cool down. Start by 

unscrewing the two phillips 

screws that hold the lamp 

door in place. DO NOT 

UNSCREW THE SCREW 

LOCTATED ABOVE THE 

MAIN SCREWS!

Pull the lamp door out and 

rotate to the side as the 

diagram shows. You will 

not have access to the 

lamp. 

  Vizi Hybrid 16RX                              Lamp & Fuse Replacement

Caution:

 Always replace with the exact same type lamp and fuse, 

unless otherwise specified by an authorized ADJ

®

 service technician. 

Replacing with anything other than  the specified  part  can  damage 

your unit and will void your manufactures warranty.

Warning: 

If you continue to blow lamps or fuses, STOP using the 

unit. Contact customer support for further instructions, you may have 

to return the unit for servicing. Continuing to use the unit may cause 

serious damage.

Fuse Replacement:

  First  unplug  the  power.  The  fuse  holder  is 

located next to the PowerCon connection. Using a phillips head screw 

driver unscrew the fuse holder. Remove the bad fuse and replace with 

a new one. 

Lamp Replacement:

 

Caution! Never attempt to change the 

lamp  while  the  fixture  is  plugged  in.  Always  disconnect  the 

main power and allow the unit at least 15 minutes to cool before 

attempting to replace the lamp. Please see page 7 for important 

information regarding the discharge lamp.  See  the  next  pages 

for lamp replacement instructions. Be sure to follow the proper 

handling procedures that deal with discharge lamps.

  Vizi Hybrid 16RX   

                        Photometric Chart

5.0

10.0

20.0

Distance(m) 

0

0m(     ) 

770000

220000

55000

5

0.41

0.81

1.6

Diameter(m) 

(LUX)

Summary of Contents for Vizi Hybrid 16RX

Page 1: ...rands and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipm...

Page 2: ...or initial operation You may also visit us on the web at www adj com for any comments or suggestions Service Hours are Monday through Friday 8 00 a m to 4 30 p m Pacific Standard Time Voice 800 322 6...

Page 3: ...rticular attention to cords at plugs convenience recep tacles and the point where they exit from the appliance Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 4...

Page 4: ...placeing the lamp you must clear the LAMP RUNNING TIME see page 29 Lamp Use Hour Warning DO NOT use this lamp more then 1500 hours Using the lamp any longer then the set life could seriously damage yo...

Page 5: ...including calculat ing working load limits installation material being used and perodic safety inspection of all installation material and unit If you lack these qualifications do not attempt the inst...

Page 6: ...ower Switch Turns On Off the power 1 LED POWER On Power on DMX On DMX input present 2 Display To show thevarious menus and the selectedfunction 3 Button MENU To enter into move backward or leave the m...

Page 7: ...X cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cables should be mad...

Page 8: ...er s faders to control the various DMX fixture traits 5 For longer cable runs more than a 100 feet use a terminator on the last fixture 6 For help operating in DMX mode consult the manual included wit...

Page 9: ...LIGHT GREEN PURPLE 43 44 PURPLE 45 46 PURPLE PINK 47 48 PINK 49 50 PINK MEDIUM YELLOW 51 52 MEDIUM YELLOW 53 54 MEDIUM YELLOW CTB 55 56 CTB 57 58 CTB UV 59 60 UV 61 63 UV WHITE 64 127 COLOR INDEXING...

Page 10: ...127 INDEXING 128 189 COUNTER CLOCKWISE ROTATION FAST SLOW 190 193 NO ROTATION 194 255 CLOCKWISE ROTATION SLOW FAST 13 SHUTTER STROBE 0 7 SHUTTER CLOSED 8 15 SHUTTER OPEN 16 131 STROBING SLOW FAST 132...

Page 11: ...UT WITH PAN TILT MOVEMENT 80 89 DISABLE BLACKOUT WITH PAN TILT MOVEMENT 90 99 ENABLE BLACKOUT WITH COLOR CHANGE 100 109 DISABLE BLACKOUT WITH COLOR CHANGE 110 119 ENABLE BLACKOUT WITH GOBO CHANGE 120...

Page 12: ...ns to switch between YES and NO Selecting YES will activate pan inverse NO will deactivate the function 4 Press ENTER to confirm your selection or press the MENU button Vizi Hybrid 16RX System Menu Vi...

Page 13: ...ss the UP or DOWN buttons until BLO P T Moving is dis played and press ENTER The current setting will now be displayed 3 Use the UP or DOWN buttons to switch between YES and NO Selecting YES will acti...

Page 14: ...Press ENTER to confirm your selection or press the MENU button to return to the main menu DISPLAY SETTING Display Inverse With this function you can flip the display 180 degrees 1 Access the main menu...

Page 15: ...confirm your selection or press the MENU button to return to the main menu Vizi Hybrid 16RX System Menu FIXTURE INFORMATION Fixture Use Hour With this function you can check the fixture run ning time...

Page 16: ...is displayed and press ENTER 3 Use the UP or DOWN buttons to switch between No or Yes To reset the pan tilt motors select Yes and press ENTER Effects With this function you can reset the effect motor...

Page 17: ...ustment for the Shutter 1 Press the ENTER button for at least 3 seconds then press the UP or DOWN buttons so that Shutter is displayed press ENTER 2 Use the UP and DOWN buttons to make your adjustment...

Page 18: ...P or DOWN buttons so that Prism2 is displayed press ENTER 2 Use the UP and DOWN buttons to make your adjustments and then press ENTER to confirm Press the MENU button for one second to exit R Prism2 S...

Page 19: ...mperature is higher than 105 C or 221 F The unit will then run on a lower power level Lamp On Over 700 Hour This will appear when the lamp has been on over 700 hours When this appears you need to turn...

Page 20: ...void your manufactures warranty Warning If you continue to blow lamps or fuses STOP using the unit Contact customer support for further instructions you may have to return the unit for servicing Cont...

Page 21: ...ing will ensure longevity and crisp out put 1 Use normal glass cleaner and a soft cloth to wipe down the out side casing 2 Use a brush to wipe down the cooling vents and fan grill 3 Clean the external...

Page 22: ...LLC factory unless prior written authorization was issued to purchaser by ADJ Products LLC if the product is damaged because not properly maintained as set forth in the instruction manual D This is n...

Reviews: