background image

ADJ Products, LLC  -  www.adj.com  - Vizi Beam Hybrid 2R Instruction Manual Page 27

  Vizi Beam Hybrid 2R 

 

 

           System Menu

1. Press the MODE/ESC button to access the main menu. Press the 

UP or DOWN buttons so that “Personality” is highlighted, then press 

ENTER. 
2. Press the UP or DOWN buttons until “Status Setting” is dis-

played, press ENTER.

3. Press  UP or DOWN buttons, until “Pan Reverse” is displayed, 

and press ENTER. 
4. Either “Off” or “On” will be displayed, use the UP and DOWN but-

tons to toggle between.
5. Press ENTER to confirm your selection or press MODE/ESC to 

exit.

Tilt Reverse - With this function you can reverse the Tilt movement.

1. Press the MODE/ESC button to access the main menu. Press the 

UP or DOWN buttons so that “Personality” is highlighted, then press 

ENTER. 
2. Press the UP or DOWN buttons until “Status Setting” is dis-

played, press ENTER.
3. Press  UP or DOWN buttons, until “Tilt Reverse” is displayed, and 

press ENTER. 
4. Either “Off” or “On” will be displayed, use the UP and DOWN but-

tons to toggle between.
5. Press ENTER to confirm your selection or press MODE/ESC to 

exit.

Pan Degree - With this function you can change the pan degree from 

630 to 540.

1. Press the MODE/ESC button to access the main menu. Press the 

UP or DOWN buttons so that “Personality” is highlighted, then press 

ENTER. 
2. Press the UP or DOWN buttons until “Status Setting” is dis-

played, press ENTER.
3. Press  UP or DOWN buttons, until “Pan Degree” is displayed, and 

press ENTER. 

ADJ Products, LLC  -  www.adj.com  - Vizi Beam Hybrid 2R Instruction Manual Page 32

  Vizi Beam Hybrid 2R 

 

 

 

 System Menu

tons to toggle between.
5. Press ENTER to confirm your selection or press MODE/ESC to 

exit.

Key Lock - With this function activated the buttons will lock autom-

matically after 15 seconds.

1. Press the MODE/ESC button to access the main menu. Press the 

UP or DOWN buttons so that “Personality” is highlighted, then press 

ENTER. 
2. Press the UP or DOWN buttons until “Display Setting” is dis-

played, press ENTER.
3. Press  UP or DOWN buttons, until “Key Lock” is displayed, and 

press ENTER. 
4. Either “Off” or “On” will be displayed, use the UP and DOWN but-

tons to toggle between.
5. Press ENTER to confirm your selection or press MODE/ESC to 

exit.

Temperature C/F - With this function, you can change the tempera-

ture display to show either Celsius or Fahrenheit.

1. Press the MODE/ESC button to access the main menu. Press the 

UP or DOWN buttons so that “Personality” is highlighted, then press 

ENTER. 
2. Press  UP or DOWN buttons, until “Temperature C/F” is dis-

played, and press ENTER. 
3. Either “Celsius” or “Fahrenheit” will be displayed, use the UP and 

DOWN buttons to toggle between.
4. Press ENTER to confirm your selection or press MODE/ESC to 

exit.

Initial Status- In this menu you are able to check initial effect posi-

tion.

1. Press the MODE/ESC button to access the main menu. Press the 

UP or DOWN buttons so that “Personality” is highlighted, then press 

Summary of Contents for Vizi Beam Hybrid 2R

Page 1: ...LLC 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 323 582 2650 Fax 323 725 6100 Web www adj com E mail info americandj com A D J Supply Europe B V Junostraat 2 6468 EW Kerkrade Netherlands service a...

Page 2: ...nd direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe unsufficient and negligent as sembly...

Page 3: ...ion 6 Important Discharge Lamp Warnings 7 Mounting 8 Controls and Functions 10 DMX Set Up 13 System Menu 16 Error Codes 38 Operation 40 DMX Traits 42 Lamp Replacement 54 Fuse Replacement 54 Cleaning 5...

Page 4: ...n shipping charges only to a designated point within the United States If the entire instrument is sent it must be shipped in it s original package No accessories should be shipped with the product If...

Page 5: ...fied service personnel when A Objects have fallen or liquid has been spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or...

Page 6: ...sure not to confuse the spare fuse with active fuse Vizi Beam Hybrid 2R Lamp Replacement Caution Always replace with the exact same type lamp and fuse unless otherwise specified by an authorized ADJ...

Page 7: ...this manual with the unit for future reference Vizi Beam Hybrid 2R General Instructions Caution There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will v...

Page 8: ...lamp explosion which could lead to hot glass particles falling from the fix ture Failure to change the lamp within 300 hours of operation will result in automatic shut down of the fixture s electroni...

Page 9: ...g removing or servicing the unit Overhead mounting requires extensive experience including calculat ing working load limits installation material being used and perodic safety inspection of all instal...

Page 10: ...the temperatures stated above This will allow the fixture to run at its best and help prolong the fixture life ADJ Products LLC www adj com Vizi Beam Hybrid 2R Instruction Manual Page 9 ADJ Products L...

Page 11: ...S 0 19 COLOR CHANGE NORMAL 20 29 COLOR CHANGE TO ANY POSITION 30 39 COLOR GOBO CHANGE TO ANY POSITION 40 59 LAMP ON 60 79 LAMP OFF 80 84 ALL MOTOR RESET 85 87 SCAN MOTOR RESET 88 90 COLOR MOTOR RESET...

Page 12: ...oving head may severely damage the unit and will void the unit warranty 11 Lamp Assembly and Access Plate This plate accesses the lamp socket assembly The unit includes a spring mounted discharge lamp...

Page 13: ...5 amp protective fuse Never defeat the fuse the fuse is designed to protect the electronics in the event of severe power fluctuations Always be sure to replace the fuse with an exact match as the one...

Page 14: ...s of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX and Master Slave Operation The...

Page 15: ...or which is con nected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line Using a c...

Page 16: ...Hybrid 2R Set Up ADJ Products LLC www adj com Vizi Beam Hybrid 2R Instruction Manual Page 44 Vizi Beam Hybrid 2R 10 Channel DMX Mode Channel Value Function 5 PRISM GOBO MACROS 208 215 MACRO 11 216 22...

Page 17: ...ee Key Lock Temperature C F Celsius Fahrenheit Temperature switch between Initial Status PAN XXX Initial effect position Reset Default ON OFF Restore factory set Reset Function Reset All Reset Pan Til...

Page 18: ...s function will allow you to see the DMX value of each DMX channel that is currently being used at the time 1 Access the main menu and press the UP or DOWN buttons so that Function is highlighted then...

Page 19: ...to change the operating mode Vizi Beam Hybrid 2R System Menu ADJ Products LLC www adj com Vizi Beam Hybrid 2R Instruction Manual Page 41 Vizi Beam Hybrid 2R Operation DOWN buttons select Alone and pr...

Page 20: ...Elation Show Designer to control head movement the color wheel gobo wheel prism master dimmer shutter strobe and vari ous other features A DMX controller allows you to create unique pro grams tailore...

Page 21: ...ess ENTER or press MODE ESC to exit Lamp Off Time This will allow you to check the running time of the lamp the last time that the lamp was On 1 Press the MODE ESC button to access the main menu Press...

Page 22: ...ode brings all the internal motors to a home position If there is an internal problem with one or more of the motors an error code will flash in the display in the form of XXer XX will represent a fun...

Page 23: ...ection or press MODE ESC to exit Temperature Info This will allow you to check the moving head temperature 1 Press the MODE ESC button to access the main menu Press the UP or DOWN buttons so that Info...

Page 24: ...o access the main menu Press the UP or DOWN buttons so that Lamp Control is highlighted then ADJ Products LLC www adj com Vizi Beam Hybrid 2R Instruction Manual Page 36 Vizi Beam Hybrid 2R System Menu...

Page 25: ...press ENTER 2 Press the UP or DOWN buttons until Lamp Off Via DMX is dis played press ENTER 3 Either Off or On will be displayed use the UP and DOWN but ADJ Products LLC www adj com Vizi Beam Hybrid 2...

Page 26: ...p is higher then the preset value for longer then 5 mins the unit will automatically shut Off the lamp If the lamp is automatically shut off due to over heat it can not be restriked automatically it m...

Page 27: ...o toggle between 5 Press ENTER to confirm your selection or press MODE ESC to exit Pan Reverse With this function you can reverse the Pan movement Vizi Beam Hybrid 2R System Menu ADJ Products LLC www...

Page 28: ...s dis played press ENTER 3 Press UP or DOWN buttons until Pan Degree is displayed and press ENTER ADJ Products LLC www adj com Vizi Beam Hybrid 2R Instruction Manual Page 32 Vizi Beam Hybrid 2R System...

Page 29: ...ER to confirm your selection or press MODE ESC to exit ADJ Products LLC www adj com Vizi Beam Hybrid 2R Instruction Manual Page 31 Vizi Beam Hybrid 2R System Menu 2 Press the UP or DOWN buttons until...

Page 30: ...n press ENTER Vizi Beam Hybrid 2R System Menu ADJ Products LLC www adj com Vizi Beam Hybrid 2R Instruction Manual Page 29 Mic Sensitivity With this function you can set the microphone sensitivity The...