ADJ ULTRA GO PAR7X User Instructions Download Page 5

ADJ Products, LLC  -  www.adj.com  - Ultra Go Par7X User Manual Page 9

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

 Ultra Go Par7X 

 

                                           Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs  of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ Products, LLC part number Z-DMX/T) will decrease the possibili-

ties of erratic behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

ADJ Products, LLC  -  www.adj.com  - Ultra Go Par7X User Manual Page 8

P

ower Supply:

 The ADJ Ultra Go Par7X contains a automatic volt-

age switch, which will auto sense the voltage when it is plugged into 

the power source. With this switch there is no need to worry about the 

correct power voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Ultra Go Par7X can be controlled via DMX protocol. The Ultra Go 

Par7X has 8 DMX channel modes, please see pages 10-11 for the dif-

ferent modes. The DMX address is set on the back panel of the Ultra Go 

Par7X. Your unit and your DMX controller require 

a  standard  3-pin  XLR  connector  for  data  input 

and data output (Figure 1). We recommend Accu-

Cable DMX cables. If you are making your own 

cables,  be  sure  to  use  standard  110-120  Ohm 

shielded cable (This cable may be purchased at 

almost all pro lighting stores). Your cables should 

be made with a male and female XLR connector 

on either end of the cable. Also remember that 

DMX cable must be daisy chained and cannot be 

split.

  Ultra Go Par7X                                                         Set Up

Figure 1

Summary of Contents for ULTRA GO PAR7X

Page 1: ...is document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged All non ADJ Products LLC brands and product names are trademarks or registered trademar...

Page 2: ...Par7X Installation Ultra Go Par7X Introduction ADJ Products LLC www adj com Ultra Go Par7X User Manual Page 2 Unpacking Thank you for purchasing the Ultra Go Par7X by ADJ Prod ucts LLC Every Ultra Go...

Page 3: ...ltra Go Par7X User Manual Page 4 To reduce the risk of electrical shock or fire do not expose this unit rain or moisture Do not spill water or other liquids into or on to your unit Do not attempt to o...

Page 4: ...ment please contact ADJ customer support 800 322 6337 3 7 Do Not use a damaged Battery The battery could be damaged during shipping caused by shock Should the battery be found damaged including dam ag...

Page 5: ...ductor 5 Pin XLR Male In 3 Pin XLR Female Out Pin 1 Do Not Use Do Not Use Pin 3 Pin 2 Pin 1 Pin 3 Pin 2 Not Used Not Used Data True signal Data Compliment signal Ground Shield 3 Pin XLR to 5 Pin XLR C...

Page 6: ...6 FS XX will be displayed this is Flash mode The Flash can be adjusted between FS 00 flash off to FS 15 fastest flash Ultra Go Par7X Operating Instructions Operating Power There are two ways to supply...

Page 7: ...l modes will return to their default settings ADJ Products LLC www adj com Ultra Go Par7X User Manual Page 12 Ultra Go Par7X Operating Instructions Sound Active Mode In this mode the Ultra Go Par7X wi...

Page 8: ...mode of operation 4 On the Slave unit press the MODE button until SLAv is dis played The Slave unit will now follow the Master Ultra Go Par7X Master Slave Configuration 1 Plug the fixture in and pres...

Page 9: ...Flash Button to activate strobing and use the or to adjust the Flash rate FLASH This button will activate the flash strobe effect You can control the flash speed by pressing the and buttons SPEED Pre...

Page 10: ...ACROS See 1 Channel DMX mode for colors Ultra Go Par7X 5 Channel DMX Values Functions ADJ Products LLC www adj com Ultra Go Par7X User Manual Page 18 Ultra Go Par7X 2 Channel DMX Values Functions Chan...

Page 11: ...el Value Function 8 COLOR CHANGE MODE CONT 192 223 COLOR CHANGE 7 224 255 COLOR CHANGE 8 COLOR FADE MODE 0 31 COLOR FADE 1 32 63 COLOR FADE 2 64 95 COLOR FADE 3 96 127 COLOR FADE 4 128 159 COLOR FADE...

Page 12: ...ar7X Fuse Replacement With this feature you can connect the fixtures to one another using the IEC input and output sockets The quantity that can be connected is 12 fixtures maximum After 12 fixtures y...

Page 13: ...ove ADJ Products LLC will replace defective parts at its expense with new or refurbished parts and will absorb all expenses for warranty service and repair labor by reason of defects in material or wo...

Page 14: ...Mode 7 Channel Mode Warranty 3 Year 1 095 days This depends on charging frequency See Warranty page for details Please Note Specifications and improvements in the design of this unit and this manual...

Reviews: