System Menu: When making adjustments press ENTER to confirm your setup then press and 

hold the MENU button for at least 3 seconds. To exit without making any adjust-ments press 

the MENU button. The display will lock after 30 seconds, press the MENU button for 3 sec-

onds to unlock.

Addr - DMX Address Setting.

1.  Press the either the MENU, UP, or DOWN buttons until “Addr” is displayed. Press ENTER.

2.  The current address will now be displayed and flashing. Press the UP or DOWN buttons to find 

your desired address. Press ENTER to set your desired DMX address.

Chnd - This will let you select your desired DMX channel mode.

1.  Press the either the MENU button until “Chnd” is displayed, press ENTER. The current DMX 

channel mode will be displayed.

2.  Press the UP or DOWN buttons to find your desired DMX channel mode and press ENTER to 

confim and exit.

dnSt - This setting defines the behavior of the fixture in the event that the DMX signal is lost, 

interrupted, or power is lost.  

1.  Press the MENU button until “dnSt” is displayed, and either “BLND or “LAST” will be displayed 

beneath.

2.  Press ENTER and the bottom choice will begin to flash. Use the UP or DOWN buttons to choose 

an operating mode you would like the unit to start up in when power is applied or the DMX signal 

is lost.

•  BLND (Blackout) - If the DMX signal is lost or interrupted, the unit will automatically go into 

stand by mode.

•  HOLD - If the DMX signal is lost the fixture will stay in the last DMX setting. If power is ap-

plied and this mode is set, the unit will automatically go into the last DMX set up.

3.  Press ENTER to confirm your desired set up.

dInd - This will let select your desired dimmer curve.

1.  Press the MENU button until “dInd” is displayed, and press ENTER. 1 of 6 dimmer curves will be 

displayed. See the Dimmer Curve Chart section of this manual for details.

•  “STDA” (standard)

•  “STGE” (stage)

•  “TV” (TV)

•  “ARAL” (Architectural)

•  “THAL” (Theatre)

•  (Stage 2)

2.  Press the UP or DOWN buttons to find your desired dimmer curve and press ENTER to confim 

and exit.

  

  

Par ZP100 3K 

                                                                                           

System Menu

Summary of Contents for Par ZP100 3K

Page 1: ...User Manual PAR ZP100 3K...

Page 2: ...with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and opera tion of this pro...

Page 3: ...3K is a DMX intelligent zooming LED par fixture The Par ZP100 3K operates as a stand alone fixture This fixture is suitable for theaters studios retail stores and other similar locations For best resu...

Page 4: ...ny resulting damages caused by the non obser vance of this manual or any unauthorized modification to this unit Par ZP100 3K Features DMX 512 Protocol Compatible 4 DMX Channel Modes 1 2 3 or 4 channel...

Page 5: ...mount this unit in an area that will allow proper ventilation Allow about 6 15cm between this device and a wall Do not attempt to operate this unit if it has been damaged This unit is intended for in...

Page 6: ...ion when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assi...

Page 7: ...he last unit to avoid erratic behavior A terminator is a 110 120 ohm 1 4 watt resistor which is connected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female...

Page 8: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 8 Par ZP100 3K System Menu...

Page 9: ...ior of the fixture in the event that the DMX signal is lost interrupted or power is lost 1 Press the MENU button until dnSt is displayed and either BLND or LAST will be displayed beneath 2 Press ENTER...

Page 10: ...dimming and strobing Fine dimming and strobing are only used with 3 channel mode 1 Press the MENU button until NAnd is displayed then press ENTER 2 Use the UP and DOWN buttons to scroll through the se...

Page 11: ...section of this manual as well as the set up specifications that are included with your DMX controller 3 Use the controller s faders to control the various DMX fixture traits 4 This will allow you to...

Page 12: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 12 Par ZP100 3K 1 Channel Mode Par ZP100 3K 2 Channel Mode...

Page 13: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 13 Par ZP100 3K 3 Channel Mode...

Page 14: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 14 Par ZP100 3K 4 Channel Mode...

Page 15: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 15 Par ZP100 3K Dimmer Curve Chart...

Page 16: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 16 Par ZP100 3K Dimensional Drawings...

Page 17: ...in a place where it is out of the reach of people s grasp Par ZP100 3K Unit Power Linking With this feature you can connect the fixtures to one another using the power input and output sockets The qua...

Page 18: ...e normal glass cleaner and a soft cloth to wipe down the outside casing 2 Use a brush to wipe down the cooling vents and fan grill 3 Clean the external optics with glass cleaner and a soft cloth every...

Page 19: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 19 Par ZP100 3K Notes...

Page 20: ...penses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the produ...

Page 21: ...or Temperature 3000K Working Position Any Safe Secure Position Warranty 2 Year 730 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change wit...

Page 22: ......

Reviews: