background image

  

Par ZP100 3K 

                                                                                              

DMX Set Up

ADJ Products, LLC  -  www.adj.com  - Par ZP100 3K User Manual Page 6

Power Supply: The ADJ Par ZP100 3K contains an automatic voltage switch, which will auto sense 

the voltage when it is plugged into the power source. With this switch there is no need to worry 

about the correct power voltage, this unit can be plugged in anywhere.

DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and 

controller manufacturers as a form of communication between intelligent fixtures and controllers. A 

DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as 

serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals locat-

ed on all DMX fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: DMX is a language allowing all makes and models of different manufactures to be 

linked together and operate from a single controller, as long as all fixtures and the controller are DMX 

compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use 

the shortest cable path possible. The order in which fixtures are connected in a DMX line does not 

influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed 

anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is 

assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that 

unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements: The Par ZP100 3K can be controlled via DMX-512 pro-

tocol. The Par ZP100 3K has four DMX channel modes; 1 channel mode, 2 channel mode, 3 chan-

nel mode, & 4 channel mode. The DMX address is set electronically using the controls on the rear 

panel of the unit. Your unit and your DMX controller require an approved DMX-512 110 Ohm Data 

cable for data input and data output (Figure 1). We recommend Accu-Cable DMX cables. If you are 

making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be 

purchased at almost all professional sound and lighting stores). Your cables should be made with a 

male and female XLR connector on either end of the cable. Also remember that DMX cable must be 

daisy chained and cannot be split.

Summary of Contents for Par ZP100 3K

Page 1: ...User Manual PAR ZP100 3K...

Page 2: ...with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and opera tion of this pro...

Page 3: ...3K is a DMX intelligent zooming LED par fixture The Par ZP100 3K operates as a stand alone fixture This fixture is suitable for theaters studios retail stores and other similar locations For best resu...

Page 4: ...ny resulting damages caused by the non obser vance of this manual or any unauthorized modification to this unit Par ZP100 3K Features DMX 512 Protocol Compatible 4 DMX Channel Modes 1 2 3 or 4 channel...

Page 5: ...mount this unit in an area that will allow proper ventilation Allow about 6 15cm between this device and a wall Do not attempt to operate this unit if it has been damaged This unit is intended for in...

Page 6: ...ion when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assi...

Page 7: ...he last unit to avoid erratic behavior A terminator is a 110 120 ohm 1 4 watt resistor which is connected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female...

Page 8: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 8 Par ZP100 3K System Menu...

Page 9: ...ior of the fixture in the event that the DMX signal is lost interrupted or power is lost 1 Press the MENU button until dnSt is displayed and either BLND or LAST will be displayed beneath 2 Press ENTER...

Page 10: ...dimming and strobing Fine dimming and strobing are only used with 3 channel mode 1 Press the MENU button until NAnd is displayed then press ENTER 2 Use the UP and DOWN buttons to scroll through the se...

Page 11: ...section of this manual as well as the set up specifications that are included with your DMX controller 3 Use the controller s faders to control the various DMX fixture traits 4 This will allow you to...

Page 12: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 12 Par ZP100 3K 1 Channel Mode Par ZP100 3K 2 Channel Mode...

Page 13: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 13 Par ZP100 3K 3 Channel Mode...

Page 14: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 14 Par ZP100 3K 4 Channel Mode...

Page 15: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 15 Par ZP100 3K Dimmer Curve Chart...

Page 16: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 16 Par ZP100 3K Dimensional Drawings...

Page 17: ...in a place where it is out of the reach of people s grasp Par ZP100 3K Unit Power Linking With this feature you can connect the fixtures to one another using the power input and output sockets The qua...

Page 18: ...e normal glass cleaner and a soft cloth to wipe down the outside casing 2 Use a brush to wipe down the cooling vents and fan grill 3 Clean the external optics with glass cleaner and a soft cloth every...

Page 19: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 19 Par ZP100 3K Notes...

Page 20: ...penses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the produ...

Page 21: ...or Temperature 3000K Working Position Any Safe Secure Position Warranty 2 Year 730 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change wit...

Page 22: ......

Reviews: