Universal DMX Control: This function allows you to use a universal DMX-512 controller to control 

the dimmer, fine dimmer and strobe. A DMX controller allows you to create unique programs tailored 

to your individual needs.

1.  The Par ZP100 3K has 4 DMX channel modes; 1 channel mode, 2 channel mode, 3 channel 

mode, 4 channel mode. See the Channel Mode sections of this manual for detailed descriptions 

of the DMX values and traits.

2.  To control your fixture in DMX mode, follow the set-up procedures in the DMX Set Up section of 

this manual, as well as the set-up specifications that are included with your DMX controller.

3.  Use the controller’s faders to control the various DMX fixture traits.

4.  This will allow you to create your own programs.

5.  Follow the instructions shown in the System Menu section of this manual to select your DMX 

channel mode and set your desired DMX address.

6.  For longer cable runs (more than a 100 feet) use a terminator on the last fixture.

7.  For help operating in DMX mode consult the manual included with your DMX controller.

  

Par ZP100 3K 

                                                                                       

DMX Operation

  

Par ZP100 3K 

                                                                     

Beam Angle Adjustment

To adjust the beam angle slide the beam angle adjuster located inside/in front of the lens. See dia-

gram below. 

The beam angle can be adjusted manually, between 9°/ 15°/ 20°/25°/ 30°.

Summary of Contents for Par ZP100 3K

Page 1: ...User Manual PAR ZP100 3K...

Page 2: ...with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and opera tion of this pro...

Page 3: ...3K is a DMX intelligent zooming LED par fixture The Par ZP100 3K operates as a stand alone fixture This fixture is suitable for theaters studios retail stores and other similar locations For best resu...

Page 4: ...ny resulting damages caused by the non obser vance of this manual or any unauthorized modification to this unit Par ZP100 3K Features DMX 512 Protocol Compatible 4 DMX Channel Modes 1 2 3 or 4 channel...

Page 5: ...mount this unit in an area that will allow proper ventilation Allow about 6 15cm between this device and a wall Do not attempt to operate this unit if it has been damaged This unit is intended for in...

Page 6: ...ion when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assi...

Page 7: ...he last unit to avoid erratic behavior A terminator is a 110 120 ohm 1 4 watt resistor which is connected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female...

Page 8: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 8 Par ZP100 3K System Menu...

Page 9: ...ior of the fixture in the event that the DMX signal is lost interrupted or power is lost 1 Press the MENU button until dnSt is displayed and either BLND or LAST will be displayed beneath 2 Press ENTER...

Page 10: ...dimming and strobing Fine dimming and strobing are only used with 3 channel mode 1 Press the MENU button until NAnd is displayed then press ENTER 2 Use the UP and DOWN buttons to scroll through the se...

Page 11: ...section of this manual as well as the set up specifications that are included with your DMX controller 3 Use the controller s faders to control the various DMX fixture traits 4 This will allow you to...

Page 12: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 12 Par ZP100 3K 1 Channel Mode Par ZP100 3K 2 Channel Mode...

Page 13: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 13 Par ZP100 3K 3 Channel Mode...

Page 14: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 14 Par ZP100 3K 4 Channel Mode...

Page 15: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 15 Par ZP100 3K Dimmer Curve Chart...

Page 16: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 16 Par ZP100 3K Dimensional Drawings...

Page 17: ...in a place where it is out of the reach of people s grasp Par ZP100 3K Unit Power Linking With this feature you can connect the fixtures to one another using the power input and output sockets The qua...

Page 18: ...e normal glass cleaner and a soft cloth to wipe down the outside casing 2 Use a brush to wipe down the cooling vents and fan grill 3 Clean the external optics with glass cleaner and a soft cloth every...

Page 19: ...ADJ Products LLC www adj com Par ZP100 3K User Manual Page 19 Par ZP100 3K Notes...

Page 20: ...penses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the produ...

Page 21: ...or Temperature 3000K Working Position Any Safe Secure Position Warranty 2 Year 730 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change wit...

Page 22: ......

Reviews: