BEAM ANGLE ADJUSTMENT

 

To  adjust  the  beam  angle,  slide  the  beam 
angle  adjuster  located  inside/in  front  of  the 
lens. See diagram below.

 

The  beam  angle  can  be  adjusted  manually, 
between 

7°/11.5°/16

°

/20.5°/25°

.

 

DMX OPERATION 

DMX Controller

 

No need to turn the unit off when you change the DMX address, as new DMX address setting will be 
affected at once. Turn on the unit, under the DMX signal; the LED will display the saved channel 
address (001

512). 

Universal DMX Control: 

This function allows you to use a universal DMX-512 controller  to  control 

the dimmer, fine dimmer and strobe. A DMX controller allows you to create unique programs tailored 
to your individual needs.

 

1.

 

The  PAR  Z120/ZP120  RGBW  has  3  DMX  channel  modes;  1-channel  mode,  2-channel  mode 
and 3-channel mode. See page 18 for a detailed description of the DMX values and traits.

 

2.

 

To control your fixture in DMX mode, follow the set-up procedures on pages 12-15 as well as the set-
up specifications that are included with your DMX controller.

 

3.

 

Use the controller’s faders to control the various DMX fixture traits.

 

4.

 

This will allow you to create your own programs.

 

5.

 

Follow the instructions on page 9 to select your DMX channel mode and set your desired DMX 
address.

 

6.

 

For longer cable runs (more than a 100 feet) use a terminator on the last fixture.

 

7.

 

For help operating in DMX mode consult the manual included with your DMX controller. 

 

 

Summary of Contents for PAR Z120 RGBW

Page 1: ...PAR Z120 RGBW PAR ZP120 RGBW User Guide User Instructions Z120 RGBW ZP120 RGBW ...

Page 2: ... and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product ADJ USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 2650 323 532 2941 fax www adj com support americandj com ADJ Supply Europe B V Junostraat 2...

Page 3: ...w 7 DMX Setup 8 System Menu 10 Beam Angle Adjustment DMX Operation 14 Dimming Curve 15 DMX Traits 16 Remote Device Management RDM 19 Installation Multi Unit Power Linking Fuse Replacement 20 Maintenance Cleaning and Troubleshooting 21 Specification 22 Dimensions 23 Optional Accessories 24 ...

Page 4: ...scard the outer shipping carton in the trash Please recycle whenever possible CUSTOMER SUPPORT Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments or suggestions ADJ SERVICE USA Monday Friday 8 00am to 4 30pm PST Voice 800 322 6337 Fax 323 582 2941 support adj com ADJ SERVICE EUROPE Monday Friday 08 30 to 17 00 CET Voice 31 45 546...

Page 5: ...air labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of ADJ Products LLC All products covered by this warranty were manufactured after August 15 2012 and bear identifying marks to that effect E ADJ Products LLC reserves the...

Page 6: ...URFACE TEMPERATURE 185 F 85 C MAXIMUM AMBIENT TEMPERATURE 104 F 40 C DO NOT TOUCH the fixture housing during operation Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before serving DO NOT shake fixture avoid brute force when installing and or operating fixture DO NOT operate fixture if the power cord is frayed crimped damaged and or if any of the power cord conn...

Page 7: ...7 OVERVIEW MENU To select the programming functions DOWN To go forward in the selected functions UP To go backward in the selected functions ENTER To confirm the selected functions ...

Page 8: ...troller knows to send DATA assigned to address 1 to that unit no matter where it is in the DMX chain Data Cable DMX Cable Requirements For DMX Operation This fixture can be controlled via DMX 512 protocol The DMX address is set using the control panel Your unit and your DMX controller require a 5 pin XLR connector for data input and data output We recommend Accu Cable DMX cables If you are making ...

Page 9: ...ior A terminator is a 110120 ohm 1 4 watt resistor which is connected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line Using a cable terminator ADJ part number Z DMX T will decrease the possibilities of erratic behavior ...

Page 10: ...sing the ENTER button Use DOWN and UP button to change the mode Once the required mode has been selected press ENTER button to setup or it will return to the main functions without any change after idling 8 seconds automatically To go back to the functions without any change press the MENU button The main functions are shown below ...

Page 11: ...chosen in the setup is the running mode the fixture will go into when the DMX signal is lost You can also set this as the operating mode you would like the unit to return to when power is applied Press the MENU button until is displayed and press ENTER Use the DOWN and UP button to select Blackout or Automatic Operation Color Macro or Hold the last state Press ENTER and the bottom choice will begi...

Page 12: ...l is displayed and press ENTER Use the DOWN and UP button to select Red Green or Blue You can also choose values between 125 255 Once selected press ENTER to confirm and exit or exit menu mode without any change after 8 seconds automatically Manual mode Press the MENU button until is displayed and press ENTER Use the DOWN and UP buttons to select the Red Green Blue White Dimmer or Strobe Press ENT...

Page 13: ...Display the running time of the unit Select the press ENTER button and the display will show the number of working hours of the unit Press ENTER to confirm and exit or exit menu mode without any change after 8 seconds automatically LED Usage time Select the press ENTER button and the display will show the number of working hours of the LED To go back to the functions press the MENU button Firmware...

Page 14: ...ows you to create unique programs tailored to your individual needs 1 The PAR Z120 ZP120 RGBW has 3 DMX channel modes 1 channel mode 2 channel mode and 3 channel mode See page 18 for a detailed description of the DMX values and traits 2 To control your fixture in DMX mode follow the set up procedures on pages 12 15 as well as the set up specifications that are included with your DMX controller 3 U...

Page 15: ...15 DIMMING CURVE The fixture includes 6 different dimming curve modes that can selected from either the system menu or via DMX The graph below provides details on each dimming curve mode ...

Page 16: ... 0 255 Dimmer 0 100 5 Channel Mode Channel Value Function 1 R 0 255 Dimmer 0 100 2 G 0 255 Dimmer 0 100 3 B 0 255 Dimmer 0 100 4 W 0 255 Dimmer 0 100 5 0 255 Total Dimmer 0 100 6 Channel Mode Channel Value Function 1 R 0 255 Dimmer 0 100 2 G 0 255 Dimmer 0 100 3 B 0 255 Dimmer 0 100 4 W 0 255 Dimmer 0 100 5 0 255 Total Dimmer 0 100 6 0 255 Dimming Fine ...

Page 17: ...LEDs ON 6 0 255 TotalDimmer 0 100 7 0 255 Dimmingfine 8 Channel Mode Channel Value Function 1 R 0 255 Dimmer 0 100 2 G 0 255 Dimmer 0 100 3 B 0 255 Dimmer 0 100 4 W 0 255 Dimmer 0 100 5 Strobe 0 31 Shutter Closed LEDs OFF 32 63 Shutter OPEN LEDs ON 64 95 Strobe Effect Slow to Fast 96 127 Shutter OPEN LEDs ON 128 159 Strobe Pulse Slow to Fast 160 191 Shutter OPEN LEDs ON 192 223 Random StrobeSlow t...

Page 18: ...18 DMX TRAITS CHANNEL FUNCTIONS AND VALUES 9 Channel Mode ...

Page 19: ...reen including the DMX Address DMX Channel Mode and Temperature Sensors FIXTURE RDM INFORMATION RDM Code Device ID Device Model ID Personality ID 0X667 OPEN 1639 OPEN Please be aware that not all RDM devices support all RDM features and therefore it is important to check beforehand to ensure that the equipment that you are considering includes all the features that you require The following parame...

Page 20: ...ugh to maintain the DMX circuit when the power to one of the units is disconnected At the last fixture use a line terminator see DMX Set Up on page 9 Each lighting fixture needs to have an address set to receive the data sent by the controller The address number is between 0 512 usually 0 1 are equal to 1 The maximum number of fixtures that can be connected on one power cable is 15 fixtures at 120...

Page 21: ... every 30 60 days 5 Always be sure to dry all parts completely before plugging the unit back in Trouble Shooting Listed below are a few common problems that you may encounter with solutions No light output from the unit 1 Be sure the external fuse has not blown The fuse is located on the rear panel of the unit 2 Be sure the fuse holder is completely and properly seated Not responding to DMX Contro...

Page 22: ... gel frame for diffusion filters Diffusion filter sold separately Strobe effect Flicker Free Operation Electronic Dimming 0 100 with 5 dimming curves Run all night No duty cycle Electrical Power Draw Total All LED s Full On 107W Multi voltage operation AC 100 240V 50 60Hz Daisy chain 14 fixtures 120V 27 fixtures 230V Dimensions Weight Dimensions LxWxH 19 5 x 11 x 9 491 x 275 x 224mm Weight 8 5 lbs...

Page 23: ...23 DIMENSIONS Dimensions not to scale ...

Page 24: ...ause undesired operation FCC RADIO FREQUENCY INTERFERENCE WARNINGS INSTRUCTIONS This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This device uses and can radiate radio frequency energy and if not installed and used in accordance with ...

Page 25: ......

Reviews: