TORQUE SETTINGS FOR SCREWS:
ALL SCREWS MUST BE TIGHTENED WITH A TORQUE DRIVER. All screws are Allen Head
screws. Please see below for screw locations, screw quantity and torque settings. The number listed
in the “#” column corresponds to the location on the fixture. See the fixture diagram and number on
the next page for SCREW LOCATION depictions.
# Screw Locations
Screw Torque Settings
1 Heat Sink to Head Front Cover (x8)
7.5-10.0 In-Lb
2 Sealed Back Cover to Head Back Cover (x4)
7.5-10.0 In-Lb
3 Yoke Arm Cover to Yoke Frame (8 x Each Side = 16 Total)
7.5-10.0 In-Lb
4 Access Cover to Yoke Frame (x4)
7.5-10.0 In-Lb
5 2nd Access Cover to Yoke Frame (x8)
7.5-10.0 In-Lb
6 Power & Data Connector to Base Casting (x10)
6.0-8.5 In-Lb
7 Handle to Base Casting (2 x Each Side = 4 Total)
Fasten by Air Screwdriver
8 Base Bottom Cover to Base Casting (x12)
7.5-10.0 In-Lb
9 Quick Lock Plate to Base Bottom Cover (x16)
7.5-10.0 In-Lb
10 Fixture Feet to Base Bottom (x4)
6.0-8.5 In-Lb
11
TORQUE SETTINGS & IP TESTER
TORQUE DRIVERS (Recommended):
UTICA TS-30 (Shown)
ALTERNATIVE DRIVERS:
Proto J6107A
Wiha 28887
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES! TO
CONFIRM THE IP65 INTEGRITY AFTER A LAMP REPLACEMENT, TEST THE FIXTURE USING
THE IP TESTER.
Summary of Contents for HYD190
Page 1: ...User Manual HYDRO WASH X19 USA HYD190 EU 1237000302 UPC 818651028232...
Page 12: ...12 TORQUE SCREW LOCATIONS...
Page 30: ...30 PIXEL ZONES 26 CHANNEL MODE 88 CHANNEL MODE 91 CHANNEL MODE...
Page 44: ...TARGET MODES 44 TARGET MODE 3 TARGET MODE 4...
Page 45: ...DIMMER CURVE CHART 45...
Page 46: ...ERROR CODES 46...
Page 47: ...DIMENSIONAL DRAWINGS 47...
Page 52: ......