ADJ ENCORE LP7IP User Manual Download Page 1

User Manual

ENCORE LP7IP

Summary of Contents for ENCORE LP7IP

Page 1: ...User Manual ENCORE LP7IP ...

Page 2: ...es injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and opera tion of this product Europe Energy Saving Notice Energy Saving Matters EuP 2009 125 EC Saving electric energy is a key to help protecting the...

Page 3: ...ty Guidelines 7 Overview 8 Installation 9 Remote Device Management RDM 12 Control Panel 13 System Menu 14 DMX Setup 17 DMX Traits 19 Color Macros Chart 22 Dim Modes 24 Daisy Chain Power Linking Cleaning and Maintenance 25 Dimensional Drawings 26 Specifications 27 Accessory and Ordering Information 28 ...

Page 4: ... this manual with the unit for future reference Customer Support Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments or suggestions Parts To purchase parts online visit http parts adj com US http www adjparts eu EU ADJ SERVICE USA Monday Friday 8 00am to 4 30pm PST Voice 800 322 6337 Fax 323 582 2941 support adj com ADJ SERVICE EU...

Page 5: ...arranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of ADJ Products LLC All products covered by this warranty were manufactured after August 15 2012 and bear identifying marks to that effect E ADJ Pr...

Page 6: ...he Encore LP7IP carries a 2 year limited warranty Please fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompanied by a return authorization R A number The R A number must be clearly writ ten on the outside of the return package A brief description of the problem as well as the R A num ber must als...

Page 7: ...XIMUM AMBIENT TEMPERATURE IS 113 F 45 C DO NOT OPERATE THE DEVICE WHEN AMBIENT TEMPERATURE EXCEEDS THIS VALUE MINIMUM DISTANCE TO FLAMMABLE MATERIALS FROM THE SURFACE IS 1 6 FEET 0 5 METER DO NOT TOUCH the fixture housing during operation Turn OFF the power and allow approximately 60 minutes for the fixture to cool down before serving DO NOT shake fixture and avoid brute force when installing and or ...

Page 8: ...8 OVERVIEW ...

Page 9: ...tructure or surface is properly certified to safely hold the combined weight of the fixture s clamps cables and accessories Maximum fixture ambient operating temperature is 113 F 45 C Do not use operate the fixture when ambient temperature exceeds this value Fixture s should be installed in areas outside walking paths seating areas or areas were unau thorized personnel might reach the fixture by hand...

Page 10: ...he yoke and attach a separate SAFETY CABLE of the appropriate weight rating to the safety cable loop SAFETY CABLE ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THAT THE FIXTURE WILL NOT FALL IF THE CLAMP FAILS CONNECTIONS Ensure all connections and end caps are properly sealed with a dielectric grease available at most electrical suppliers to pr...

Page 11: ...s irises shutters motors belts wiring discharge lamps and LEDs This issue is not unique to ADJ lighting fixtures it is a common issue with lighting fixtures from all manufacturers Although there is no true way to fully prevent this issue from happening the guide lines below can reduce the risk of any potential damage if followed Contact ADJ Service for more details DO NOT EXPOSE THE FIXTURE AND OR...

Page 12: ...ible RDM enabled con troller to send out a signal to devices on the wire as well as allowing the fixture to respond known as a GET command The controller can then use its SET command to modify settings that would typically have to be changed or viewed directly via the unit s display screen including the DMX Address DMX Channel Mode and Temperature Sensors Please be aware that not all RDM devices s...

Page 13: ...or confirm selection This device features two different settings for locking the keypad Setting Lock to ON requires the user to simply press and hold the MODE button for 10 seconds to unlock the keypad Setting Lock to ON1 provides an additional safeguard against accidental unlocking by requiring a passcode to unlock the device To unlock press the MODE button so that LOCKED is dis played on the scr...

Page 14: ... PERSONALITY Primary On Off Set primary mode Secondary On Off Set secondary mode Fan Set Auto High Silent Dim Mode Standard Stage TV Archi Theatre Stage 2 Dim Speed 0 1s 10s Dim Curve Square Linear Inv Squa S Curve LED Rfrsh 900 1000 1100 1200 1300 1400 1500 2500 4000 5000 10k 15k 20k 25k Set LED refresh rate default 1200 Hz Display SaveDelay 1 10 Lock ON Press MODE for 10s to unlock ON1 Press MOD...

Page 15: ...000 255 Manually adjust strobing MastrDim 000 255 Master dimmer AutoProg 000 255 Select automatic program ProgSpd 000 255 Set program speed ProgFade 000 255 Set program fade INTPROGS Prog 0 Speed 000 255 Fade 000 255 Prog 1 Speed 000 255 Fade 000 255 Prog 7 Speed 000 255 Fade 000 255 INFO Hours PwrOnHr1 xxx Hrs Total hours that fixture has been powered on Non resettable PwrOnHr2 xxx Hrs Hours that...

Page 16: ...16 SYSTEM MENU INFO contin ued DMX Values Red Displays current DMX values for each DMX channel Green AutoProg SoftVers x xx Displays current software version ...

Page 17: ...ixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The Encore LP7IP can be controlled via DMX 512 protocol and features multiple DMX channel modes Your unit and your DMX control ler require a 5 pin XLR connector for data input and data outpu...

Page 18: ...e DMX address will cause all fixtures to react in the same way In this case please note that changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel num ber you have set based on the quantity of DMX channels of each fixture That means changing the settings of one channel will o...

Page 19: ...olor Temperature 2700K 7000K Linear 7 7 7 Color Temperature Macros 000 Off 001 054 2700K 055 109 3200K 110 164 4000K 165 219 5600K 220 255 6500K 5 8 8 8 Shutter Strobe 000 031 LEDs Off 032 063 LEDs On 064 095 Strobe effect slow to fast 096 127 LEDs On 128 159 Pulse effect in sequences 160 191 LEDs On 192 223 Random strobe effect slow to fast 224 255 LEDs On 6 9 9 9 000 255 Dimmer Intensity 0 100 7...

Page 20: ... 041 060 Stage 061 080 TV 081 100 Architectural 101 120 Theatre 121 140 Stage 2 141 0 1s dim speed 142 0 2s dim speed 143 0 3s dim speed 144 0 4s dim speed 145 0 5s dim speed 146 0 6s dim speed 147 0 7s dim speed 148 0 8s dim speed 149 0 9s dim speed 150 1 0s dim speed 151 1 5s dim speed 152 2 0s dim speed 153 3 0s dim speed 154 4 0s dim speed 155 5 0s dim speed 156 6 0s dim speed 157 7 0s dim spe...

Page 21: ...061 080 S Curve 081 255 No function 13 16 Refresh Rate 000 015 Default to Unit Setting 016 030 900 Hz 031 045 1000 Hz 046 060 1100 Hz 061 075 1200 Hz 076 090 1300 Hz 091 105 1400 Hz 106 120 1500 Hz 121 135 2500 Hz 136 150 4000 Hz 151 165 5000 Hz 166 180 10000 Hz 181 195 15000 Hz 196 210 20000 Hz 211 225 25000 Hz 226 255 No Function ...

Page 22: ...4 83 14 053 056 255 93 182 93 15 057 060 255 96 236 96 16 061 064 238 93 255 93 17 065 068 196 87 255 87 18 069 072 150 90 255 90 19 073 076 100 77 255 77 20 077 080 77 100 255 77 21 081 084 67 148 255 67 22 085 088 77 195 255 77 23 089 092 77 234 255 77 24 093 096 158 255 144 144 25 097 100 255 251 153 153 26 101 104 255 175 147 147 27 105 108 255 138 186 138 28 109 112 255 147 251 147 29 113 116...

Page 23: ...2 163 0 46 181 184 0 38 86 0 47 185 188 0 142 208 0 48 189 192 52 148 209 0 49 193 196 1 134 201 0 50 197 200 0 145 212 0 51 201 204 0 121 192 0 52 205 208 0 129 184 0 53 209 212 0 83 115 0 54 213 216 0 97 166 0 55 217 220 1 100 167 0 56 221 224 0 40 86 0 57 225 228 209 219 182 0 58 229 232 42 165 85 0 59 233 236 0 46 35 0 60 237 240 8 107 222 0 61 241 244 255 0 0 0 62 245 248 0 255 0 0 63 249 252...

Page 24: ...24 DIM MODES ...

Page 25: ...ree months to make sure the circuit contacts are in good condition and prevent overheating Be sure all screws and fasteners are securely tightened at all times Loose screws may fall out during normal operation resulting in damage or injury as larger parts could fall Check for any deformations on the housing color lenses rigging hardware and rigging points ceiling suspension trussing Deformations i...

Page 26: ...26 DIMENSIONAL DRAWINGS Dimensions may not be drawn to scale ...

Page 27: ...Inv Squa S Curve Adjustable Refresh Rate 14 presets from 900 25 000Hz Flicker Free operation No flickering on camera LED pulse and strobe effect Electronic Dimming 0 100 6 DMX Modes 4 7 8 10 13 16 channel Quiet fan mode CONSTRUCTION IP65 Rated Ingress Protection against liquid snow dust and sand All metal construction IP Rated rubber covers protect In Out Locking Power connectors and IP rated 5 pi...

Page 28: ... INFORMATION SKU NUMBER DESCRIPTION ENC327 ADJ Encore LP7IP ELP7L100 100 degree Frost Filter ELP7L60 60 degree Frost Filter ELP7L20 20 degree Frost Filter ELP7L30X60 30x60 degree Frost Filter ELP7L1X40 1x40 degree Frost Filter ...

Page 29: ...29 ...

Page 30: ......