OPERATING AND USER MANUAL Q-12 CoaXPress series
________________________________________________________________________________________________________________
_________________________________________________________________________________________
Adimec
13
4.2.2 CoaXPress status LEDs
Next to the CoaXPress connector a multi-color LED status indicator is present. The meaning for each LED
indication is shown in Table 4-3, while Table 4-4 lists the frequencies of the fast and slow flashes.
Table 4-3: The meaning of the LED status indicator explained.
LED indication
Camera / interface status
Off
No power
Solid orange
System booting
Slow pulse orange
Device / Host connected, waiting for event
(e.g. trigger, exposure pulse)
500 ms red pulse. In case of multiple
errors, there shall be at least two green
fast flash pulses before the next error is
indicated.
Error during data transfer (e.g. CRC error,
single bit error detected)
Fast flash red
System error (e.g. internal error)
Solid green
Device / Host connected, but no data
being transferred
Fast flash green
Device / Host connected, data being
transferred
Fast flash alternate green / orange.
Shown for a minimum of 1 s even if the
connection detection is faster
Connection detection in progress, PoCXP
active
Slow flash alternate green / orange
Connection test packets being sent
Slow flash alternate red / green / orange Compliance test mode enabled
Table 4-4: LED indicator flash frequency
Flash indication
Frequency
Fast flash
12.5 Hz
Slow flash
0.5 Hz
Slow pulse
1 Hz