For Cyanoacrylates and Solvents

 

For Thick Fluids

 

2/3 maximum 

fill

 

Caution: 

Do not completely fill barrels. The optimum fill is a maximum 2/3 of the barrel capacity  

 

If the fluid you are dispensing is pourable, take the barrel, twist on a tip cap and pour your fluid in. If 

appropriate, insert the PE piston (see page 13). Carefully press the piston down until it contacts the flu-

id. The barrel is now ready for use. 

 

If you are dispensing solvents, cyanoacrylates or anaerobics, use the Easy-Flow piston.  

 

If your fluid is thick or non-levelling, you can spoon it into the barrel with a spatula Or, if the fluid comes 

packed in a 1/10 gallon cartridge, try loading the barrel with a caulking gun. Then press in the PE piston 

to move the fluid to the bottom of the barrel and to remove trapped air. 

Easy-Flow

 

Fill procedure for cyanoacrylates 
or watery-thin fluids

 

Fill procedure for thick fluids 
(shown: caulk gun)

 

1/2 maximum fill

 

Fill procedure for 
pourable fluids

 

2/3 maximum 
fill

 

1/2 maximum fill

 

Summary of Contents for TS9150

Page 1: ...Sales and service www adhesivedispensers co uk info adhesivedispensers co uk Tel 44 0 1908 686660 Fax 44 0 1908 686836 TS9150 Precision Fluid Dispenser USER GUIDE...

Page 2: ...his guide However if you need assistance please contact us or your authorised ADL dis tributor In the UK call free 0800 094 0958 In the US call 866 735 4456 Our Promise We pledge that you will be comp...

Page 3: ...Power and compressed air should be available where the dispenser is to be set up Air pressure should be between 80 and 100 psi 5 5 and 6 9 bar If you are not using an ADL five micron filter regulator...

Page 4: ...air 100 psi max Power cord Foot pedal assembly Check voltage label on dispenser Adapter assembly Male quick connect insert and twist to lock Sales and service www adhesive dispensing co uk info adhes...

Page 5: ...its of Watery thin Fluids on page 10 if applicable Attach the 10cc barrel 910 N to the 10cc adapter head 71003RHB Take the 10cc barrel adapter assembly 71003RHB on the adapter head and insert the yell...

Page 6: ...Controls and Connections Sales and service www adhesive dispensing co uk info adhesivedispensers co uk...

Page 7: ...initial tests Always set the pressure desired by turning the air regulator knob clockwise To reduce the pressure turn the knob counter clockwise until the gauge reads a lower pressure than desired Th...

Page 8: ...h the tip filled turn off the timer bypass switch orange light out Take the Dot Test sheet supplied and put the tip on a 1 4 circle holding the barrel as shown Press the foot pedal Check the dot size...

Page 9: ...effect of using a smaller diameter tip Replace the green tip with the blue 22 gage tapered tip Now turn on the timer bypass switch and press the foot pe dal to fill the tip Then turn off the timer byp...

Page 10: ...clip tightly closed to prevent any dripping or bubbling Remove the tip cap and attach the 25 gage red TE715050PK tip 3 Set air pressure at 5 psi 4 Press the timer bypass switch orange light on 5 With...

Page 11: ...d adjust vacuum as necessary Now the fluid is in proper balance It does not bubble or drip Repeat tests as before keeping the air pressure low and ad Some things to remember If you do not use the pist...

Page 12: ...ed air with a slight suck back movement after the dispense cycle The white PE piston is used for most fluids However if you are applying RTV silicone and find that the piston bounces and causes string...

Page 13: ...dripping Note If you use watery thin fluids such as solvents cyanoacrylates and anaerobics specify the blue Easy Flow pistons Available in 3cc 5cc 10cc and 30 55cc sizes For Thinner Fluids PE White pi...

Page 14: ...ow ready for use If you are dispensing solvents cyanoacrylates or anaerobics use the Easy Flow piston If your fluid is thick or non levelling you can spoon it into the barrel with a spatula Or if the...

Page 15: ...tom up If the fluid comes packed in a 1 10 gallon 310 ml caulking type cartridge use the ADL 900 110 barrel loader 2 If you receive frozen epoxies or other fluids in medical type syringes with a manua...

Page 16: ...dis pensed 1 Use White PE pistons or Easy Flow Blue to prevent this See pages 12 13 2 If it occurs attach an empty barrel put timer bypass switch on put barrel in a cup and press the pedal to expel th...

Page 17: ...nts contamination and provides proper safe ty 3 Do not completely fill the barrel For most fluids optimum fill is a maximum 2 3 of the barrel capaci ty For cyanoacrylates or watery thin fluids optimum...

Page 18: ...90BTE 27 927050 TE n a 927050 45BTE 927050 90BTE 30 930050 TE n a 930050 45BTE 930050 90BTE 32 932050 TE n a n a n a 34 934025 TE n a n a n a www adhesivedispensers co uk info adhesivedispensers co u...

Page 19: ...enser prepaid to the Warehouse In no event shall any liability or obligation of ADL arising from this warranty exceed the purchase price of the equipment Before using user shall determine the suitabil...

Page 20: ...Unit 501 Milton Keynes Business Centre Foxhunter Drive Milton Keynes MK14 6GD UK Tel 44 0 1908 686660 Fax 44 0 1908 686836 Main Switchboard 44 0 1908 686661 www adhesive dispensing co uk email info a...

Reviews: