User Manual   

IEC 61850 Server / PROFINET Master 

 

Document code: MN67B82_ENG     Revision 1.000    Page 6 of 26

 

 

CHARACTERISTICS: 

 

The HD67B82-A1 is a IEC 61850 Server / PROFINET Master converter. 

 

 

It allows the following characteristics: 

 

Up to 1500 bytes in reading and 1500 bytes in writing; 

 

Two-directional information between PROFINET and IEC 61850; 

 

Mountable on 35mm Rail DIN; 

 

Wide power supply input range: 8…24V AC or 12…35V DC; 

 

Wide temperature range:  -40°C / 85°C [-40°F / +185°F]. 

 
 

CONFIGURATION: 
 

You need Compositor SW67B82 software on your PC in order to perform the following: 

 

Define the parameter of the IEC 61850; 

 

Define the parameter of the PROFINET; 

 

Define the list of PROFINET slaves connected to the converter; 

 

Define the list of IEC 61850 variables available for reading and writing; 

 

Update the device.  

Summary of Contents for HD67B82-A1

Page 1: ...FINET Master from to www adfweb com Product HD67B45 OPC UA Server www adfweb com Product HD67B70 Serial www adfweb com Product HD67B71 Modbus Slave www adfweb com Product HD67B72 PROFIBUS Slave www ad...

Page 2: ...25 WARRANTIES AND TECHNICAL SUPPORT 26 RETURN POLICY 26 Pagina 2 di 26 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following d...

Page 3: ...erlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation...

Page 4: ...ronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IEC 61850 Server PROFINET Master Document code MN67B82_ENG Revision 1 000 Page 4 of 26 EXAMPL...

Page 5: ...b com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IEC 61850 Server PROFINET Master Document code MN67B82_ENG Revision 1 000 Page 5 of 26 Figure 1 Connection schem...

Page 6: ...s in reading and 1500 bytes in writing Two directional information between PROFINET and IEC 61850 Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range...

Page 7: ...r PROFINET Master Document code MN67B82_ENG Revision 1 000 Page 7 of 26 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin...

Page 8: ...he device has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second w...

Page 9: ...y slowly 0 5Hz update in progress 3 BF bus fault red ON The Ethernet connection is defective the IP address exists several times in the network the own NameOfStation exists several times in the networ...

Page 10: ...e Ethernet connection must be made using Connector3 and Connector4 of HD67B82 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to th...

Page 11: ...rter use the available software that runs with Windows called SW67B82 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the las...

Page 12: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable IEC 61850 Server PROFINET Master Converter in order to...

Page 13: ...n there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the sectio...

Page 14: ...438 30 91 31 User Manual IEC 61850 Server PROFINET Master Document code MN67B82_ENG Revision 1 000 Page 14 of 26 In the section Software Settings it is possible to enable disable some keyboard s comma...

Page 15: ...ressing the Check Box field This feature is used for going out of the net In the field Name of Station the name of the PROFINET node is defined The means of the fields for IEC61850 Server are In the f...

Page 16: ...vices Present in Network window PROFINET ACCESS By Pressing the PROFINET Access button from the main window for SW67B82 Fig 2 the window Definition of PROFINET Devices Present in Network appears Fig 4...

Page 17: ...ess the IP Address of the PROFINET slave is defined If the field Automatic new session when StationProblemIndicator is Active is checked the converter opens a new communication session when an error i...

Page 18: ...les of PROFINET Device appears Fig 5 In the main table it is possible to import the Modules of the PROFINET device in use In the properties below it is possible to set the parameters of the slave Thes...

Page 19: ...of the IEC 61850 variable is defined In the field Type the data format of the IEC 61850 variable is defined If the field Read Only is checked the IEC 61850 variable is just in reading Otherwise it is...

Page 20: ...TIFICATE By pressing the TLS Known Certificate button from the Main Window of SW67B82 Fig 2 the Definition the list of Known Certificates window appears Fig 7 The data of the columns have the followin...

Page 21: ...Turn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations a...

Page 22: ...he LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator pri...

Page 23: ...l IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IEC 61850 Server PROFINET Master Document code MN67B82_ENG Revision 1 000 Page 23 of 26 MECHANICAL DIMENSIONS Figure 10...

Page 24: ...t number is formed by a valid combination of the following HD67B82 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67B82 IEC 61850 Server P...

Page 25: ...opean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an app...

Page 26: ...ish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information a...

Reviews: