background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

OPC UA Server / CAN 

 

Document code: MN67B33_ENG     Revision 1.000    Page 26 of 27

 

 

DISCLAIMER: 
 

All technical content within this document can be modified without notice. The content of the document is a under continual renewal. 
For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal 
conditions repairs are charged to the user. ADFweb.com S.r.l. will not be liable for accidental loss of use or inability to use this product, such 
as loss of business income. ADFweb.com S.r.l. shall not be liable for consequences of improper use. 
 
 

OTHER REGULATIONS AND STANDARDS: 
 

WEEE

 INFORMATION

 

Disposal  of  old  electrical  and  electronic  equipment  (as  in  the  European  Union  and  other  European  countries  with  separate 
collection systems). 

 

This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish. Instead, it 

should  be  taken  to  an  applicable  collection  point  for  the  recycling  of  electrical  and  electronic  equipment.  If  the  product  is  disposed 
correctly,  you  will  help  prevent  potential  negative  environmental  factors  and  impact  of  human  health,  which  could  otherwise  be 
caused  by  inappropriate  disposal.  The  recycling  of  materials  will  help  to  conserve  natural  resources.  For  more  information  about 
recycling this product, please contact your local city office, your household waste disposal service or the shop where you purchased 
the product. 
 
 

R

ESTRICTION OF 

H

AZARDOUS 

S

UBSTANCES DIRECTIVE

 

 

The  device  respects  the  2002/95/EC  Directive  on  the  restriction  of  the  use  of  certain  hazardous  substances  in  electrical 
and electronic equipment (commonly referred to as Restriction of Hazardous Substances Directive or RoHS). 

 
 

CE

 MARKING

 

 

The product conforms with the essential requirements of the applicable EC directives. 

 
 

 
 

Summary of Contents for HD67B33-B2

Page 1: ...ster www adfweb com Product HD67B30 Modbus TCP Slave www adfweb com Product HD67B31 Bacnet Master www adfweb com Product HD67B32 Bacnet Slave www adfweb com Product HD67B34 CANopen www adfweb com Prod...

Page 2: ...IES AND TECHNICAL SUPPORT 27 RETURN POLICY 27 Pagina 2 di 27 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is...

Page 3: ...etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembl...

Page 4: ...al Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server CAN Document code MN67B33_ENG Revision 1 000 Page 4 of 27 EXAMPLE OF CO...

Page 5: ...es ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server CAN Document code MN67B33_ENG Revision 1 000 Page 5 of 27 Figure 1 Connection scheme for H...

Page 6: ...tional information between CAN and OPC UA Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor S...

Page 7: ...Server CAN Document code MN67B33_ENG Revision 1 000 Page 7 of 27 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax Vm...

Page 8: ...ce has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second with Dip...

Page 9: ...s quickly Boot state Blinks very slowly 0 5Hz update in progress 2 CAN comm yellow Flashing CAN message OFF No CAN messages Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 OPC...

Page 10: ...evision 1 000 Page 10 of 27 CAN For terminating the CAN line with a 120 resistor it is necessary that the Dip1 of Dip Switch B is at ON position Cable characteristics DC parameter Impedance 70 Ohm m A...

Page 11: ...e Ethernet connection must be made using Connector3 of HD67B33 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms re...

Page 12: ...e the available software that runs with Windows called SW67B33 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last versi...

Page 13: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable OPC UA Server CAN Converter in order to configure anot...

Page 14: ...is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connec...

Page 15: ...ne 39 0438 30 91 31 User Manual OPC UA Server CAN Document code MN67B33_ENG Revision 1 000 Page 15 of 27 In the section Software Settings it is possible to enable disable some keyboard s commands for...

Page 16: ...ubNet Mask the SubNet Mask for OPC UA side of the converter is defined In the field Gateway the default gateway of the net is defined This feature can be enabled or disabled pressing the Check Box fie...

Page 17: ...4 This section is used to define the list of OPC UA variables to read write The means of the checkboxes inside the table are In the field Type the data format of the OPC UA variable is defined In the...

Page 18: ...The field TimeOut is used for put at zero the data on OPC UA side if the CAN frame doesn t arrives with a frequency less than the time expressed in the field If the value in the field is 0 it means th...

Page 19: ...cument code MN67B33_ENG Revision 1 000 Page 19 of 27 In the Field Add B7 the seventh byte where the data will be saved in the internal array is defined only if Dimension 6 In the Field Add B8 the eigh...

Page 20: ...nsion the number of byte of the CAN message is defined In the field Send Frame Type it is possible to select when sending the CAN frame There are two options the first is On Data Change the frame is s...

Page 21: ...n the internal array is defined only if Dimension 4 In the Field Add B6 the sixth byte where the data will be loaded in the internal array is defined only if Dimension 5 In the Field Add B7 the sevent...

Page 22: ...N the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK t...

Page 23: ...y to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you...

Page 24: ...b com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server CAN Document code MN67B33_ENG Revision 1 000 Page 24 of 27 MECHANICAL DIMENSIONS Figure 9 Mechanic...

Page 25: ...ing part number is formed by a valid combination of the following HD67B33 A 1 Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67B33 OPC UA Ser...

Page 26: ...untries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable...

Page 27: ...exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about th...

Reviews: