CHARACTERISTICS: 

 

The HD67B29-B2 is a OPC UA Server / Modbus TCP Master converter. 

 

It allows the following characteristics: 

 

Up to 1500 bytes in reading and 1500 bytes in writing; 

 

Two-directional information between Modbus TCP and OPC UA; 

 

Mountable on 35mm Rail DIN; 

 

Wide power supply input range: 8…24V AC or 12…35V DC; 

 

Wide temperature range:  -40°C / 85°C [-40°F / +185°F]. 

 
 

CONFIGURATION: 
 

You need Compositor SW67B29 software on your PC in order to perform the following: 

 

Define the parameter of OPC UA line; 

 

Define the parameter of Modbus TCP line; 

 

Update the device.  

Summary of Contents for HD67B29-B2

Page 1: ...HD67B30 Modbus TCP Slave www adfweb com Product HD67B31 Bacnet Master www adfweb com Product HD67B32 Bacnet Slave www adfweb com Product HD67B33 CAN www adfweb com Product HD67B34 CANopen www adfweb c...

Page 2: ...ANTIES AND TECHNICAL SUPPORT 26 RETURN POLICY 26 Pagina 2 di 26 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document...

Page 3: ...rlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation...

Page 4: ...tronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server Modbus TCP Master Document code MN67B29_ENG Revision 1 000 Page 4 of 26 EXAMPL...

Page 5: ...eb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server Modbus TCP Master Document code MN67B29_ENG Revision 1 000 Page 5 of 26 CONNECTION SCHEME Figure...

Page 6: ...converter It allows the following characteristics Up to 1500 bytes in reading and 1500 bytes in writing Two directional information between Modbus TCP and OPC UA Mountable on 35mm Rail DIN Wide power...

Page 7: ...Modbus TCP Master Document code MN67B29_ENG Revision 1 000 Page 7 of 26 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin...

Page 8: ...he device has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second w...

Page 9: ...t state Blinks very slowly 0 5Hz update in progress 2 OPC UA comm yellow Flashing OPC UA requests OFF No OPC UA requests Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 Modbus...

Page 10: ...RNET The Ethernet connection must be made using Connector3 of HD67B29 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 n...

Page 11: ...rter use the available software that runs with Windows called SW67B29 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the las...

Page 12: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable OPC UA Server Modbus TCP Master Converter in order to...

Page 13: ...there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section...

Page 14: ...438 30 91 31 User Manual OPC UA Server Modbus TCP Master Document code MN67B29_ENG Revision 1 000 Page 14 of 26 In the section Software Settings it is possible to enable disable some keyboard s comman...

Page 15: ...ture can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field DNS the IP Address of the DNS server is defined This feature can be enabled or d...

Page 16: ...anual OPC UA Server Modbus TCP Master Document code MN67B29_ENG Revision 1 000 Page 16 of 26 The means of the fields for NTP Network Time Protocol are In the field Server URL the URL or the IP Address...

Page 17: ...ars Fig 4 This section is used to define the list of OPC UA variables to read write The means of the checkboxes inside the table are In the field Type the data format of the OPC UA variable is defined...

Page 18: ...he data that arrives from OPC UA side to the Modbus TCP slaves MODBUS READ The means of the fields are If the field Enable is checked the Modbus request is enabled In the field Slave IP Address the IP...

Page 19: ...f the field Swap is checked the bytes of the Modbus registers are swapped If the field Swap Word is checked the words of the 32 bit values are swapped In the field Mnemonic the description for the req...

Page 20: ...ld On CMD is checked the converter sends the writing request when the data from OPC UA is received In the field Max Error the number of consecutive errors that the converter waits before suspending th...

Page 21: ...Turn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations a...

Page 22: ...r PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure t...

Page 23: ...rl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server Modbus TCP Master Document code MN67B29_ENG Revision 1 000 Page 23 of 26 Figure 8 Mechanical dimensions s...

Page 24: ...number is formed by a valid combination of the following HD67B29 B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67B29 OPC UA Server Mod...

Page 25: ...pean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an appl...

Page 26: ...ish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information a...

Reviews: