background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l.           

User Manual 

EtherNet/IP Master / KNX - Converter

 

 

Document code: MN67806_ENG     Revision 1.000   Page 2 of 25

 

 

INDEX: 

 

 

Page 

INDEX 

UPDATED DOCUMENTATION 

REVISION LIST 

WARNING 

TRADEMARKS 

SECURITY ALERT 

EXAMPLE OF CONNECTION 

CONNECTION SCHEME 

CHARACTERISTICS 

CONFIGURATION 

POWER SUPPLY 

FUNCTION MODES 

LEDS 

KNX 

10 

ETHERNET  

11 

USE OF COMPOSITOR SW67806 

12 

NEW CONFIGURATION / OPEN CONFIGURATION 

13 

SOFTWARE OPTIONS 

14 

SET COMMUNICATION 

16 

ETHERNET/IP ACCESS 

17 

KNX ACCESS 

18 

UPDATE DEVICE 

20 

MECHANICAL DIMENSIONS 

22 

ORDERING INFORMATIONS 

23 

ACCESSORIES 

23 

DISCLAIMER 

24 

OTHER REGULATIONS AND STANDARDS 

24 

WARRANTIES AND TECHNICAL SUPPORT 

25 

RETURN POLICY 

25 

UPDATED DOCUMENTATION: 

 

Dear  customer,  we  thank  you  for  your  attention  and  we  remind  you  that 
you need to check that the following document is: 

 

Updated 

 

Related to the product you own

 

 
To  obtain  the  most  recently  updated document,  note  the  “document  code” 
that appears at the top right-hand corner of each page of this document. 
 
With  this  “Document  Code”  go  to  web  page  www.adfweb.com/download/ 
and  search  for  the  corresponding  code  on  the  page.  Click  on  the  proper 
“Document Code” and download the updates. 

 

 

REVISION LIST: 

 

 

 

WARNING: 

 

ADFweb.com reserves the right to change information in this manual about 
our product without warning. 
ADFweb.com is not responsible for any error this manual may contain. 

 

 

 

TRADEMARKS: 

 

All  trademarks  mentioned  in  this  document  belong  to  their  respective 
owners.

Revision 

Date 

Author 

Chapter 

Description 

1.000 

05/06/2019 

Ff 

All 

First release version 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for HD67806-KNX-B2

Page 1: ...HD67804 CANopen www adfweb com Product HD67807 EtherNet IP Slave www adfweb com Product HD67808 DeviceNet Master www adfweb com Product HD67809 DeviceNet Slave www adfweb com Product HD67810 J1939 www...

Page 2: ...SUPPORT 25 RETURN POLICY 25 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product y...

Page 3: ...The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and oper...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherNet IP Master KNX Converter Document code MN67806_ENG Revision 1 000 Page 4 of 25 EXAMPLE OF CONNECTION...

Page 5: ...trial Electronic Devices ADFweb com S r l User Manual EtherNet IP Master KNX Converter Document code MN67806_ENG Revision 1 000 Page 5 of 25 CONNECTION SCHEME Figure 1 Connection scheme for HD67806 KN...

Page 6: ...rical isolation between Ethernet and KNX Mountable on 35mm Rail DIN Wide power supply input range 18 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor S...

Page 7: ...67806_ENG Revision 1 000 Page 7 of 25 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption...

Page 8: ...ing of the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is...

Page 9: ...links slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 EtherNet IP communication yellow Blinks when EtherNet IP communication is running Blinks quickly Boot state Bli...

Page 10: ...to the security to the heating monitoring to the conditioning to the hydric control and alarms to energy management and so on Characteristics Description TP1 256 Medium Shielded Twisted Pair Topology...

Page 11: ...et IP communication The Ethernet connection must be made using Connector2 of HD67806 KNX B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to co...

Page 12: ...e the Converter use the available software that runs with Windows called SW67806 It is downloadable on the site www adfweb com and its operation is described in this document The software works with M...

Page 13: ...configuration A device s configuration can also be imported or exported To clone the configurations of a Programmable EtherNet IP Master KNX Converter in order to configure another device in the same...

Page 14: ...ange the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possi...

Page 15: ...t IP Master KNX Converter Document code MN67806_ENG Revision 1 000 Page 15 of 25 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation ins...

Page 16: ...s defined fixed to KNX TP In the field ID Device the ID of the KNX side of the converter is defined The means of the fields for EtherNet IP Master are In the fields IP ADDRESS the IP address for Ether...

Page 17: ...array is defined In the field Num Input the number of consecutive Input byte to map on internal memory array is defined In the field Start Output the starting Output byte of the EtherNet IP slave to...

Page 18: ...ssage is defined You can choose between the following o Read it is used to send a reading request to a KNX device o Write it is used to send a writing request to a KNX device o Specific value edited m...

Page 19: ...byte of the field Position where start to insert the data read In the field Lenght the dimension of the KNX message is defined In the field Mnemonic the description for the request is defined Note If...

Page 20: ...Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Di...

Page 21: ...the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator p...

Page 22: ...ectronic Devices ADFweb com S r l User Manual EtherNet IP Master KNX Converter Document code MN67806_ENG Revision 1 000 Page 22 of 25 Figure 8 Mechanical dimensions scheme for HD67806 KNX B2 MECHANICA...

Page 23: ...id combination of the following HD67806 KNX B 2 Connectors Type 2 Fixed 5mm Screw Terminal Enclosure Type B 4M 35mm DIN Rail mounting Device Family HD67806 KNX EtherNet IP Master KNX Converter Order C...

Page 24: ...llection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the...

Page 25: ...ase do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the produc...

Reviews: