EXAMPLE OF CONNECTION: 

 

 

 

 

 

 

 

 

Summary of Contents for HD67718-IP-A1

Page 1: ...nverter BACnet Master to www adfweb com Product HD67704 DMX www adfweb com Product HD67712 Modbus Slave www adfweb com Product HD67714 Modbus TCP Slave www adfweb com Product HD67716 PROFIBUS Slave ww...

Page 2: ...7 WARRANTIES AND TECHNICAL SUPPORT 38 RETURN POLICY 38 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updat...

Page 3: ...vice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual BACnet Master CANopen Document code MN67718_ENG Revision 1 000 Page 4 of 38 EXAMPLE OF CONNECTION...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual BACnet Master CANopen Document code MN67718_ENG Revision 1 000 Page 5 of 38 CONNECTION SCHEME Figure 1a Connection scheme for HD67718 IP A1...

Page 6: ...Industrial Electronic Devices ADFweb com S r l User Manual BACnet Master CANopen Document code MN67718_ENG Revision 1 000 Page 6 of 38 Figure 1b Connection scheme for HD67718 MSTP A1...

Page 7: ...Industrial Electronic Devices ADFweb com S r l User Manual BACnet Master CANopen Document code MN67718_ENG Revision 1 000 Page 7 of 38 Figure 1c Connection scheme for HD67718 MSTP B2...

Page 8: ...Cnet bus and CANopen bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor HD67718 software o...

Page 9: ...NG Revision 1 000 Page 9 of 38 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V...

Page 10: ...the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used f...

Page 11: ...wered ON Device powered OFF Device not powered 3 BACnet comm green It blinks when a BACnet response is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 Device State gre...

Page 12: ...Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Link Ethernet yellow ON Ethernet cable connected OFF Ethernet cable disconnected ON Ethernet cable connected OFF Ethernet cable...

Page 13: ...ommunication The Ethernet connection must be made using Connector2 of HD67718 xxx xx with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform t...

Page 14: ...N For terminating the CAN line with a 120 resistor it is necessary that the Dip1 of Dip Switch B is at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC parameters Impedance 120 Ohm...

Page 15: ...o put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Bel...

Page 16: ...runs with Windows called SW67718 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on...

Page 17: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable BACnet Master CANopen Converter in order to configure another device in the same manne...

Page 18: ...he language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to...

Page 19: ...Cnet Master CANopen Document code MN67718_ENG Revision 1 000 Page 19 of 38 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside th...

Page 20: ...pressing the Check Box field This feature is used for going out of the net In the field Port the port used for BACnet communication is defined The default port used for BACnet communication is 47808...

Page 21: ...Rate the data rate of the CANopen line is defined In the field Set Operational State at Start Up the state of the CANopen is defined I e If it is checked the board starts in Operational State else it...

Page 22: ...t contains the data to be read is defined In the field Object Type the object to be read is defined In the field Instance the instance number of the object is defined In the field Property the propert...

Page 23: ...number of consecutive errors that the Master waits before resetting the data for the specific requests is defined In the field Position the starting byte of the internal memory array where mapping the...

Page 24: ...s defined In the field NByte the number of bytes of the BACnet object is defined By checking the field En Dest it is possible to enable the Destination Network D Net Destination Length D Len and Desti...

Page 25: ...the Master waits before stopping the specific requests is defined In the field Position the starting byte of the internal memory array from which taking the data to write is defined The field Start Bi...

Page 26: ...The data of the columns have the following meanings In the field Index the address of the SDO is defined In the field SubIndex the second address of the SDO is defined If the field N Byte the dimensio...

Page 27: ...n the field ID Device insert the ID of the device to read In the field Index the address for the SDO is defined In the field SubIndex the second address for the SDO is defined In the field N Byte the...

Page 28: ...n Change is checked the gateway sends the Write SDO request when the data change the value In the field Address Byte1 the address of the internal array where reading the first byte of the SDO write is...

Page 29: ...Field Add B2 the second byte where the data will be saved in the internal array is defined only if Dimension 1 In the Field Add B3 the third byte where the data will be saved in the internal array is...

Page 30: ...ray is defined only if Dimension 3 In the Field Add B5 the fifth byte where the data will be loaded in the internal array is defined only if Dimension 4 In the Field Add B6 the sixth byte where the da...

Page 31: ...net cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of...

Page 32: ...rogram inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program mo...

Page 33: ...al Electronic Devices ADFweb com S r l User Manual BACnet Master CANopen Document code MN67718_ENG Revision 1 000 Page 33 of 38 MECHANICAL DIMENSIONS Figure 10a Mechanical dimensions scheme for HD6771...

Page 34: ...Industrial Electronic Devices ADFweb com S r l User Manual BACnet Master CANopen Document code MN67718_ENG Revision 1 000 Page 34 of 38 Figure 10b Mechanical dimensions scheme for HD67718 MSTP A1...

Page 35: ...Industrial Electronic Devices ADFweb com S r l User Manual BACnet Master CANopen Document code MN67718_ENG Revision 1 000 Page 35 of 38 Figure 10c Mechanical dimensions scheme for HD67718 MSTP B2...

Page 36: ...ype A 1M 35mm DIN Rail mounting B 4M 35mm DIN Rail mounting BACnet port IP BACnet IP MSTP BACnet MS TP Device Family HD67718 BACnet Master CANopen Converter Order Code HD67718 IP A1 BACnet IP Master C...

Page 37: ...on systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recyc...