Document code: MN67661_ENG     Revision 1.001    Page 13 of 26

 

 

SOFTWARE OPTIONS: 

 

By  pressing  the  “

Settings

”  (

)  button    there  is  the  possibility  to  change  the  language  of  the  software  and  check  the  updatings  for  the 

compositor. 
 
In  the  section  “Language”  it  is  possible  to  change  the  language  of  the 
software. 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
In  the  section  “Connection  Options”,  it is  possible  to  check  if  there  are  some 
updatings of the software compositor in ADFweb.com website. 
Checking  the  option  “

Check  Software  Update  at  Start  of  Program

”,  the 

SW67661 check automatically if there are updatings when it is launched. 

Summary of Contents for HD67661-A1

Page 1: ...vices see also the following links EtherNet IP Master from to www adfweb com Product HD67158 SNMP Agent www adfweb com Product HD67643 PROFIBUS Slave www adfweb com Product HD67645 CAN www adfweb com...

Page 2: ...AND TECHNICAL SUPPORT 26 RETURN POLICY 26 Pagina 2 di 26 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Upd...

Page 3: ...ocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation as...

Page 4: ...ectronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET EtherNet IP Master Document code MN67661_ENG Revision 1 001 Page 4 of 26 EXAMPLE...

Page 5: ...Fweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET EtherNet IP Master Document code MN67661_ENG Revision 1 001 Page 5 of 26 CONNECTION SCHEME Figure 1...

Page 6: ...racteristics Up to 1440 bytes in reading and 1440 bytes in writing Two directional information between EtherNet IP and PROFINET Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12...

Page 7: ...erNet IP Master Document code MN67661_ENG Revision 1 001 Page 7 of 26 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vm...

Page 8: ...position of the Dip2 of Dip Switch B The first with Dip2 in Off position factory setting is used for the normal working of the device The second with Dip2 in On position is used for upload the Project...

Page 9: ...ot state Blinks very slowly 0 5Hz update in progress 3 BF bus fault red ON The Ethernet connection is defective the IP address exists several times in the network the own NameOfStation exists several...

Page 10: ...Ethernet connection must be made using Connector3 or Connector4 of HD67661 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T...

Page 11: ...er use the available software that runs with Windows called SW67661 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last...

Page 12: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable PROFINET EtherNet IP Master Converter in order to conf...

Page 13: ...here is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section C...

Page 14: ...0438 30 91 31 User Manual PROFINET EtherNet IP Master Document code MN67661_ENG Revision 1 001 Page 14 of 26 In the section Software Settings it is possible to enable disable some keyboard s commands...

Page 15: ...he default gateway of the net is defined This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field Port the port used for PROFINET...

Page 16: ...of the EtherNet IP slave to map on PROFINET side is defined In the field Num Input the number of consecutive Input byte to map on PROFINET side is defined In the field Start Output the starting Outpu...

Page 17: ...www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET EtherNet IP Master Document code MN67661_ENG Revision 1 001 Page 17 of 26 Figure 5 PROFINET XML window PROFINET XML By pressing the PROFINET...

Page 18: ...urn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are...

Page 19: ...e updating Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven...

Page 20: ...Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET EtherNet IP Master Document code MN67661_ENG Revision 1 001 Page 20 of 26 MECHANICAL DIMENSIONS Figure 8 Mec...

Page 21: ...ering part number is formed by a valid combination of the following HD67661 A 1 Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67661 PROFINET...

Page 22: ...001 Page 22 of 26 PLC CONFIGURATION The configuration and commissioning of the PROFINET Converter as described on the following pages was accomplished with the help of the TIA Portal software by Siem...

Page 23: ...iso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET EtherNet IP Master Document code MN67661_ENG Revision 1 001 Page 23 of 26 2 Import the module in the network connect the device to t...

Page 24: ...Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET EtherNet IP Master Document code MN67661_ENG Revision 1 001 Page 24 of 26 3 Load the confi...

Page 25: ...an countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applic...

Page 26: ...h to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information abo...

Reviews: