background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

EtherNet/IP / DeviceNet Master - Converter

 

 

Document code: MN67597_ENG     Revision 1.011   Pagina 24 di 25

 

 

 

DISCLAIMER 
 

All technical content within this document can be modified without notice. The content of the document content is a recurring audit. 
For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal 
conditions repairs are charged to the user. ADFweb.com S.r.l. will not be liable for accidental loss of use or inability to use this product, such 
as loss of business income. ADFweb.com S.r.l. shall not be liable for consequences of improper use. 
 
 

OTHER REGULATIONS AND STANDARDS 
 

WEEE

 INFORMATION

 

Disposal  of  old  electrical  and  electronic  equipment  (as  in  the  European  Union  and  other  European  countries  with  separate 
collection systems). 

 

This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish. Instead, it 

should  be  taken  to  an  applicable  collection  point  for  the  recycling  of  electrical  and  electronic  equipment.  If  the  product  is  disposed 
correctly,  you  will  help  prevent  potential  negative  environmental  factors  and  human  health,  which  could  otherwise  be  caused  by 
inappropriate  disposal. The  recycling  of  materials  will help  to  conserve  natural  resources.  For  more  information  about  recycling  this 
product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. 
 
 

R

ESTRICTION OF 

H

AZARDOUS 

S

UBSTANCES DIRECTIVE

 

 

The  device  respects  the  2002/95/EC  Directive  on  the  restriction  of  the  use  of  certain  hazardous  substances  in  electrical 
and electronic equipment (commonly referred to as Restriction of Hazardous Substances Directive or RoHS). 

 
 

CE

 MARKING

 

 

The product conforms with the essential requirements of the applicable EC directives. 

 

Summary of Contents for HD67597-A1

Page 1: ...ww adfweb com Product HD67599 J1939 www adfweb com Product HD67589 NMEA2000 www adfweb com Product HD67590 Serial RS232 www adfweb com Product HD67590 Serial RS485 www adfweb com Product HD67591 Modbu...

Page 2: ...and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the...

Page 3: ...hes mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar wit...

Page 4: ...c Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual EtherNet IP DeviceNet Master Converter Document code MN67597_ENG Revision 1 011 Pagina 4 di 25 EX...

Page 5: ...m Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual EtherNet IP DeviceNet Master Converter Document code MN67597_ENG Revision 1 011 Pagina 5 di 25 CONNECTION SCHEME Fig...

Page 6: ...he following characteristics Up to 500 bytes in reading and 500 bytes in writing Two directional information between CAN bus and EtherNet IP bus Mountable on 35mm Rail DIN Power Supply 8 24V AC or 12...

Page 7: ...eNet Master Converter Document code MN67597_ENG Revision 1 011 Pagina 7 di 25 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin V...

Page 8: ...on of the Dip2 of Dip Switch A The first with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for upload t...

Page 9: ...ormal Mode Boot Mode 1 Device State green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 DeviceNet State green Blinks quickly when there is communication wit...

Page 10: ...or Connector4 of HD67597 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to...

Page 11: ...Converter Document code MN67597_ENG Revision 1 011 Pagina 11 di 25 DeviceNet For terminate the CAN line with a 120 resistor it is necessary that the Dip1 of Dip Switch B is at ON position Cable charac...

Page 12: ...software works with MSWindows MS 2000 XP Vista Seven 8 32 64bit When launching the SW67595 the right window appears Fig 2 NEW PROJECT OPEN PROJECT The New Project button creates the folder which cont...

Page 13: ...that you want to give to the Converter In the fields SUBNET Mask insert the SubNet Mask In the fields GATEWAY insert the default gateway that you want to use This feature can be enabled of disabled p...

Page 14: ...ndow for SW67597 Fig 2 the window DeviceNet Network appears Fig 4 The data of the columns have the following meanings In the field ID the ID of a slave DeviceNet device is defined In the field N BYTE...

Page 15: ...ween those defined in the DeviceNet Network step The data of the column have the following meanings Byte IN side In the column Offset it is possible to select the desired byte of DeviceNet which will...

Page 16: ...w the actual IP address of the device you have to use this procedure Turn off the Device Put Dip2 of Dip Switch A at ON position Turn on the device Connect the Ethernet cable Insert the IP 192 168 2 2...

Page 17: ...mware on the device is correctly update Note When you install a new version of the software it is better if the first time you do the update of the Firmware in the HD67597 A1 device Note When you rece...

Page 18: ...31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual EtherNet IP DeviceNet Master Converter Document code MN67597_ENG Revision 1 011 Pagina 18 di 25 MECHANICAL DIMENSIONS Figure...

Page 19: ...ering part number is formed by a valid combination of the following HD67597 A 1 Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67597 EtherNet...

Page 20: ...CONFIGURATION The configuration and commissioning of the EtherNet IP Converter as described on the following pages was accomplished with the help of the RSLogix 5000 software of Rockwell Automation I...

Page 21: ...ta SINT shall be selected as the data type The HD67597 A1 can uses up to 500 bytes for input assembly instance 101 and 500 bytes for output assembly instance 100 RSLogix 5000 requires a configuration...

Page 22: ...IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual EtherNet IP DeviceNet Master Converter Document code MN67597_ENG Revision 1 011 Pagina 22 di 25 4 After the configuration...

Page 23: ...ser Manual EtherNet IP DeviceNet Master Converter Document code MN67597_ENG Revision 1 011 Pagina 23 di 25 5 With RSLinks Classic Lite after have done a network scan RSWho and finding the EtherNet IP...

Page 24: ...other European countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken...

Page 25: ...costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warra...

Reviews: