background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

Modbus Master / Ethernet 

 

 

Document code: MN67506_ENG     Revision 1.012    Page 6 of 18 

 

 

CHARACTERISTICS: 

 

The configurable ModBus Master / Ethernet Converter allow the following characteristics: 

 

TCP/UDP Ethernet protocols changeable with software; 

 

Mountable on 35mm Rail DIN; 

 

Wide power supply input range: 8…19V AC or 8…35V DC; 

 

Wide temperature range:  -40°C / 85°C [-40°F / +185°F]. 

 
 

CONFIGURATION: 

 
You need Compositor SW67506 software on your PC in order to perform the following: 

 

Define the parameter of Modbus; 

 

Define the parameter of Ethernet; 

 

Update the device. 

 
 

Summary of Contents for HD67506

Page 1: ...For others Converter Adapter Converters Adapters See also the following links www adfweb com Product HD67118 Modbus RTU Slave www adfweb com Product HD67119 Modbus TCP Master www adfweb com Product HD67120 Modbus TCP Slave For others Gateways Bridges Modbus RTU Master Slave See also the following links www adfweb com Product HD67001 CANopen www adfweb com Product HD67502 CANopen www adfweb com Pro...

Page 2: ...on and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb com download and search for the corresponding code on the page Click on the proper Document Code...

Page 3: ...device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential hazard if they are inappro...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Master Ethernet Document code MN67506_ENG Revision 1 012 Page 4 of 18 CONNECTION SCHEME Figure 1 Connection scheme HD67506 ...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Master Ethernet Document code MN67506_ENG Revision 1 012 Page 5 of 18 Figure 2 Connection scheme for HD67506M ...

Page 6: ...nverter allow the following characteristics TCP UDP Ethernet protocols changeable with software Mountable on 35mm Rail DIN Wide power supply input range 8 19V AC or 8 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67506 software on your PC in order to perform the following Define the parameter of Modbus Define the parameter of Ethernet Update the device ...

Page 7: ..._ENG Revision 1 012 Page 7 of 18 POWER SUPPLY The devices can be powered at 8 19V AC and 8 35V DC For more details see the two tables below Consumption at 24V DC Device Consumption W VA HD67506 4 HD67506M 4 VAC VDC Vmin Vmax Vmin Vmax 8V 19V 8V 35V HD67506 Caution Not reverse the polarity power HD67506M ...

Page 8: ...ow appears Fig 3 NEW PROJECT OPEN PROJECT The New Project button creates the folder which contains the entire device configuration A device configuration can also be imported and exported To clone the configurations of a orogrammable ModBus Ethernet Converterin order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in ord...

Page 9: ... Ethernet protocol used is the TCP otherwise if the field UDP is checked the Ethernet protocol used is the UDP The means of the fields for Serial are In the field Baud rate the baudrate for the Serial is defined In the field Parity the parity for the Serial is defined In the field Timeout ms there is the maximum time that the device attends for the answer from the Slave interrogated If the field R...

Page 10: ...tions Turn off the device Connect the Null Modem cable from your PC to the gateway Insert the Boot Jumper see the Fig 1 2 for more info Turn on the device Check the BOOT Led It must to blink quickly Seethe Fig 1 for more info Select COM port and press the Connect button Press the Next button Select operations you want to do Can select only Firmware or only Project or both Press the Execute update ...

Page 11: ...d the device If you are using a USB RS232 converter try with a native COM port or change the converter Try to repeat the operations for the updating Try with another PC Try to restart the PC CHARACTERISTICS OF THE CABLES ETHERNET Linking of Ethernet connector to a HUB must be carried out by a Category 5E cable The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mb...

Page 12: ...ferred into the Ethernet WRITE FRAMES The transmission has a fixed structure that consist of seven bytes plus the data Byte Number Description 1 Write Identifier Write 0x02 2 Type of Data 3 Device Address 4 Start Address Hi 5 Start Address Lo 6 Number of Point Hi 7 Number of Point Lo 8 n 1 Data n Number of Point 2 if Type of Data is 0x10 or n Number of Point 7 8 if Type of Data is 0x0F The Type of...

Page 13: ... than 1 or the frame length is wrong if the function is 15 16 0x03 Illegal data value the value referenced in the data field is not allowable in the addressed slave location 0x02 Illegal data address the address referenced in the data field is not an allowable address for the addressed slave device 0x01 Illegal function the message function received is not an allowable action for the addressed sla...

Page 14: ...transmission has a fixed structure that consist of seven byte Byte Number Description 1 Read Identifier Read 0x01 2 Type of Data 3 Device Address 4 Start Address Hi 5 Start Address Lo 6 Number of Point Hi 7 Number of Point Lo The Type of Data Byte Number 2 can have four values 0x01 Coil Status 0x02 Input Status 0x03 Holding Register 0x04 Input Register ...

Page 15: ...is wrong 0xF9 Returned function is different from the one requested 0xF8 Number of byte different from 7 0x03 Illegal data value the value referenced in the data field is not allowable in the addressed slave location 0x02 Illegal data address the address referenced in the data field is not an allowable address for the addressed slave device 0x01 Illegal function the message function received is no...

Page 16: ...thernet Converter Order Code HD67506M Modbus Master Ethernet Converter different enclosure ACCESSORIES Order Code AC34001 Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 Rail DIN Power Supply 110V AC 50 60Hz 12 V AC Order Code AC34104 European Input Power Supply 230V AC 50Hz 12 V DC Figure 8 Mechanical dimensions scheme for HD67506M Figure 7 Mechanical dimensions scheme for HD...

Page 17: ...tion systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human health which could otherwise be ca...

Page 18: ...do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exch...

Reviews: