SET COMMUNICATION:
This section defines the fundamental communication parameters of two buses, J1939 and CAN.
By pressing the “
Set Communication
” button from the main window for SW67439 (Fig. 2) the
window “Set Communication Setting” appears (Fig. 3).
The meaning of the fields of “J1939” are:
In the field “
Baudrate
” the data rate of J1939 bus is defined;
In the field “
TimeOut Data (s)
” a time is defined. When this time is expired, the data on CAN
side will be set to ‘0xFF’;
If the field “
Enable Peer to Peer
” is checked, the gateway accepts all the IDs that have the
PGNs inserted in the section “Receive J1939”;
In the field “
Device ID J1939
” the J1939 address for the converter is defined.
The meaning of the fields of “CAN” are:
In the field “
Baudrate
” the data rate of CAN bus is defined.
Figure 3: “Set Communication” window