NMEA2000 / Modbus TCP Slave
Document code: MN67225_ENG Revision 1.100 Page 16 of 30
SET COMMUNICATION:
This section defines the fundamental communication parameters
of two Buses, NMEA 2000 and Modbus TCP.
By pressing the “
Set Communication
” button from the main
window for SW67225 (Fig. 2) the window “Set communication”
appears (Fig. 3).
This window is divided in two sections, one for configure the
NMEA 2000 and the other for the Modbus TCP Slave.
In the section “Select Device” it is possible to select the type of
converter used:
Device till April 2014 (with Jumper);
Device from May 2014 (with Dip-Switches).
I
The means for the fields for the “NMEA 2000” are:
In the field “
Baud Rate
” the baudrate of the NMEA 2000 is
defined;
In the field “
TimeOut
” the timeout of the data is defined.
If this time is elapsed the value of the data of the NMEA
2000 frame become “0”. If the “Cancel Data” field is
checked in the “Receive NMEA 2000” window;
If the field “
Enable Peer to Peer
” is checked, the Source
Address of the PGNs received by the converter is masked
(only if a single NMEA device is connected);
In the field “
Device ID NMEA 2000
” the ID of the
converter is defined (only if “Device from May 2014 (with
Dip-Switches)” is selected);
Figure 3: “Set Communication” window