3.2.2 Command mode
Use a COM port terminal block to communicate with the device. We use the HERCULES COM port soft terminal available to download for
free by clicking the following link:
http://www.hw-group.com/products/hercules/index_en.html
•
With Hercules, select the “Serial” tab, then configure the serial port with the following serial parameters:
Debit
115 200 bps
Parity
None
Data
8
Stop Bit
1
Stop Bit
1
• Select the serial port on which the device was created with Windows.
• Click the “Open” button to open the serial port.
INFORMATIONAL NOTE: If the com port has been opened correctly, Hercules will display the message “Serial port COM3
opened”. Alternatively, “Serial port com opening error” will be displayed, meaning either that the com port is already open
for another application, or it does not exist.
Type ‘+++’ to switch the device to configuration mode.
On the com port terminal, you should also have a “CM” feedback for Command Mode.
Sending characters on Hercules are displayed in magenta and receiving characters in black. If
you do not see sending characters, it is probably because ECHO is not active on the software.
Activate the option in the menu, which you can access with a right click in the viewing window.