Installation Instructions
4-8
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*92
Telecom Monitor Enable
Entry 1
–Timeout:
0 = disabled
1-15 = 1 minute to 15 minutes respectively
(2 = 2 min, 3 = 3 min, etc.; # + 10 =10 min, #
+ 11 = 11 min, # + 12 = 12 min, # + 13 = 13
min, # + 14 = 14 min, # + 15 = 15 min)
Entry 2
–Display/Sound:
0 = keypad display only when phone line is
faulted.
1 = keypad display plus keypad trouble
sound when line is faulted. Each
partition turns off its own trouble sound.
No automatic timeout.
2 =
Same as “1” plus programmed output
device STARTS. If any partition is
armed, external sounder activates.
External sounder will be turned off by
normal siren timeout or by security code
plus OFF from any partition (it does not
have to be the one that was armed).
Entry 1:
Sets the length of time a phone line fault must remain after
detected before the second digit option is activated.
Entry 2:
Selects the desired phone line fault response.
Option 2 may be used even if a relay unit or Powerline carrier device
is not connected to the control.
Programmed Output Device must either be programmed to be
STOPPED in field
80 or STOPPED by entry of [security code] + [#] +
8 + device number. Partition in
80 should be set to “0,” for STOP.
*93
No. of Reports In Armed Period
per Zone (Intermittent Sensor
Suppression)
0 = unlimited number of reports
1 = 1 report pair per zone per armed period
2 = 2 report pairs per zone per armed period
This option can be used to limit the number of alarm/alarm restore
messages per zone sent to the central station in an armed period.
*94
Download Phone Number
Enter up to 20 digits as follows: 0
–9, # +11
for “
”, # + 12 for “#”, # + 13 for a pause.
Enter the phone number of the downloading computer.
Do not fill unused spaces. End field by entering
. To clear entries
from field, press
94
.
*95
Ring Count For Downloading
0 = Disable Monitoring Station initiated
downloading
1
–14 = number of rings before control
answers incoming call
#+15 = Answering machine/fax defeat
Refer to the chart below and program this field accordingly.
phone
answer/fax down-
module machine
loading
Set field
95 to…
yes
no
no
1-14 (not 0)
yes
yes
no
higher than number of rings set on
answer/fax machine (e.g., if ans/fax
machine is 4 rings, set this field to
5). This allows access via the
phone module if the answer/fax
machine is turned off.
yes
no
yes
1-14 (not 0)
yes
yes
yes
15 (bypasses answer/fax
machine
†
)
no
no
no
0
no
yes
no
0
no
no
yes
1-14
no
yes
yes
15
†
NOTE:
If “15” is entered to bypass an answering machine and a
TeleCommand Phone Module is included in the system, you should
note the following:
When calling in from an off-premises phone, the user should make the
initial call, allow 1 or 2 rings only, then hang up, then call again. The
phone module will now seize the line, and 2 long tones sound,
followed by the usual voice prompt for the access code. If this
procedure is not followed, phone module operation will not be possible.