LYNXR is not intended for UL985 Household Fire applications.

Introduction

This Quick Start Guide can help you install the rechargeable LYNXR and LYNXR24 quickly and easily by providing
the basic steps for installation using the built-in defaults.  For more detailed information and important notes, refer
to the LYNXR/LYNXR24 Installation Instructions.

The following steps assume that one of the system’s default tables will be used.
For programming data values and Powerline Carrier Devices other than those listed in the default tables, see the
Installation Instructions.

Default Table Summary

Zone

Table 1

Table 2

Table 3

Table 4

1

-------

-------

-------

-------

2

front door

front door

front door

front door

3

back door

back door

back door

back door

4

window

Garage door

window

window

5

motion detector

motion detector

window

window

6

-------

smoke detector

window

window

7

-------

-------

window

window

8

-------

-------

motion detector

motion detector

9

-------

-------

smoke detector

smoke detector

26

loop 3 arm away

loop 3 arm away

loop 3 arm away

loop 3 arm away

27

loop 2 disarm

loop 2 disarm

loop 2 disarm

loop 2 disarm

28

loop 4 arm stay

loop 4 arm stay

loop 4 close device

loop 4 close device

29

loop 1 restore device 1

loop 1 restore device 1

loop 1 restore device 1

loop 1 restore device 1

30

loop 3 arm away

loop 3 arm away

loop 3 arm away

loop 3 arm away

31

loop 2 disarm

loop 2 disarm

loop 2 disarm

loop 2 disarm

32

loop 4 arm stay

loop 4 arm stay

loop 4 close device

loop 4 close device

33

loop 1 restore device 1

loop 1 restore device 1

loop 1 restore device 1

loop 1 restore device 1

92

duress

duress

duress

duress

99

silent alarm

silent alarm

silent alarm

silent alarm

User Code

1-2-3-4

1-2-3-4

1-2-3-4

1-2-3-4

Install Code

4-1-1-2

4-1-1-2

4-1-1-2

4-1-1-2

Entering Program Mode: installer code + 8 0 0

Interactive Mode

Used to Program

*56 Enhanced Zone Programming

Zone characteristics, report codes, and serial numbers

*83 Sequential Mode

5800 Series transmitter serial numbers

*84 Assign Zone Voice Descriptors

Voice descriptors for each zone

Exiting Program Mode: *99 allows re-entry into the Program mode using Installer Code + 8  0  0.

*98 inhibits re-entry into the Programming mode using the Installer Code.

NOTES:

  •

Tables 2 and 4 support the automatic paging feature (open/close events reported to pager phone number),and a Powerline
Carrier Device programmed as device 8, which closes and stays closed upon burglary alarms and restores after bell timeout. For
other applications or actions (e.g., using a pulsing siren), see the *80 Device Programming Menu Mode section of the Installation
Instructions.

Primary report format for all tables is Ademco’s Contact ID reporting. Tables 2 and 4 also use Contact ID for secondary
reporting. Tables 1, and 3 use 4+1 format for secondary reporting.

Table 2 records all events in the event log. Tables 1, 3, and 4 record only alarms, alarm restores, troubles, and trouble restores
in their event logs.