11
ENGLISH
EXTERNAL CONNECTIONS
ALARM IN
You can connect two devices including an alarm
switch with a resistance of 1 kohm or less or a door
sensor. Connect pin
q
to pin
!5
(ground) through
the switches.
ALARM OUT
Approx. 12V is applied to pin
w
during an alarm
recording.
Notes:
• When you have selected “PULSE” in the
“ALARM OUT” menu in the ALARM display,
approx. 12V pulses will be applied to the output
after the alarm recording ends.
• When you have selected “DURATION” in the
“ALARM OUT” menu in the ALARM display, no
voltage is applied after the alarm recording
ends.
• The output impedance is approx. 100 ohm.
ONE SHOT IN
One shot recording is possible when pin
e
is
shorted to pin
!5
.
Note: Do not apply a voltage to pin
e
or
!5
.
TAPE END OUT
Approx. 12V is applied to pin
r
when the tape
reaches the end.
Notes:
• This does not operate when you have selected
“REW, RE-REC” in the “RECYCLE FUNCTIONS”
menu in the ALARM display or you have selec-
ted “REWIND, STOP IF ALARM” and no alarm
recording has been made.
• The output impedance is approx. 100 ohm.
TAPE END RESET
The TAPE END OUT function can be turned off
when pin
t
is shorted to pin
!5
.
Note: Do not apply a voltage to pin
t
or
!5
.
WARNING OUT
When an abnormality has occurred in this VCR,
approx. 5V is output to pin
y
to warn the user.
Pin Arrangement of 15-Pin Adapter
q
ALARM IN
w
ALARM OUT
e
ONE SHOT IN
r
TAPE END OUT
t
TAPE END RESET
o
CAMERA SW OUT
!0
REC START IN
!1
-
!2
-
!3
REMOTE IN
!4
REC CHECK IN
!5
GND
y
WARNING OUT
u
-
i
TIME ADJUST
11
10
9
5
4
3
2
1
8
7
6
15
14
13
12
ALARM IN
GND
q
!5
AVR960SV-A4.E 01.6.12 6:08 PM ページ 11