background image

ZW60-210531-Rev006-UM-en 

 

3

 

 

This symbol means: "Consult operating instructions". To achieve accurate re-
sults, read the instructions for use carefully before use and follow all instruc-
tions provided therein. Keep the instructions for use for future reference. 

1.  Applications 

The ZW60 series digital checkweighing scale provides accurate, fast and versatile checkwei-
ghing and simple counting options and is designed for checkweighing in applications not re-
gulated by law. 

-  The ZW60-45 scale has a rated capacity of 45 kg with a digit interval of 1 g. 

-  All scales are equipped with stainless steel weighing platforms and ABS plastic housings. 

-  All scales have sealed keypads with colour-coded membrane switches. 

-  The  display  is  a  highly  readable  liquid  crystal  display  (LCD)  with  extra  large  digits  (digit 

height is 52 mm). The LCD display is equipped with a backlight that can optionally be enab-
led or disabled. 

-  All scales have an auto zero function, an audible alarm for preset weights, an automatic 

taring, a preset taring and a totaliser that allows to save and recall the number of pieces as 
a total sum. 

-  The scale can be switched between such units as kg, g, lbs and oz. 

-  Power is supplied via a 230 V mains connection or a 6 V 4 Ah rechargeable battery. 

2.  Delivery contents 

Included in the delivery are: 

-  Scales 

-  Rechargeable battery (integrated into the scale) 

-  Weighing platform 

-  Power adapter 

-  User manual incl. declaration of conformity  

3.  Safety instructions 

It is essential that you read, understand and follow all instructions in these instructions for use 
as  well  as  the  country-specific  installation  standards,  the  applicable  safety  regulations  and 
accident prevention regulations. 

-  Handle the scale with care and always keep in mind that it is a precision measuring instru-

ment. 

-  Protect the weighing platform from impacts and vibrations and do not overload the scale. 

-  The scale may only be operated and maintained by trained and authorised skilled person-

nel. Handling errors can lead to injuries or damage the scale. 

-  Before  first  use,  make  sure  that  the  mains  voltage  and  current  type  stated  on  the  name 

plate match the mains voltage and current type at the place of use. 

-  Lay the cables so that they cannot lead to a trip hazard.  

-  Lay the cables so that they cannot pose a risk of strangulation.  

-  Operate the device only within the permissible ambient conditions. 

-  Do not expose the scale to high temperatures, whether from neighbouring devices or direct 

sunlight. 

Summary of Contents for ZW60-45

Page 1: ...OPERATING MANUAL Electronic table scales Control scale Model ZW60 45 ZW60 210531 Rev006 UM en ...

Page 2: ...roing the scale 7 6 2 Taring 7 6 3 Determining the weight 8 6 4 Weighing in percent 8 6 5 Piece counting 8 6 5 1 Method 1 Unknown reference weight 8 6 5 2 Method 2 Known reference weight 8 6 6 Presetting the maximum and minimum values for audible alarm 9 6 7 Totaliser 9 6 7 1 Manual totaliser 10 6 7 2 Automatic totaliser 10 7 Parameters 11 8 Care and maintenance 13 8 1 Cleaning 13 8 2 Error indica...

Page 3: ...between such units as kg g lbs and oz Power is supplied via a 230 V mains connection or a 6 V 4 Ah rechargeable battery 2 Delivery contents Included in the delivery are Scales Rechargeable battery integrated into the scale Weighing platform Power adapter User manual incl declaration of conformity 3 Safety instructions It is essential that you read understand and follow all instructions in these in...

Page 4: ...es 1 Carefully remove the delivery contents from the packaging 2 If necessary remove the transport lock before operating the scale The transport lock if any is located on the underside of the scale 3 Place the scale on a stable horizontal surface Do not place the scale on a shaky or vibrating table as this will cause distortion of measurement results 4 Do not place the scale near vibrating machine...

Page 5: ...on Skips the active digit one place to the right when entering values of adjustable parameters or other functions MODE Mode button Changes the units in weighing mode Changes display between unit weight counted quantity and total weight in counting mode Displays weight in percent mode The scale automatically returns to percent mode in three seconds Secondary function Skips the active digit one plac...

Page 6: ...weight value in weighing mode or the minimum quantity in counting mode If the applied weight or the applied quantity is smaller than the minimum value you will hear an audible signal To enter the value press and hold down this button for 3 seconds 0 9 Manual entry of values Numeric buttons from 0 to 9 are used to manually enter values such as unit weight or reference quantity C Clear manually ente...

Page 7: ...rgeable battery or if the rechargeable battery is used for several years without replacement it is possible that the rechargeable battery will no longer be fully charged If the rechargeable battery life becomes unacceptable contact your customer service representative or the manufacturer 6 Operation 6 1 Zeroing the scale When the gross weight is within 2 of zero a new zero point is set as when the...

Page 8: ...return to the weighing mode 6 5 Piece counting 6 5 1 Method 1 Unknown reference weight First possibly tare the empty container as described above and leave it on the weighing surface Press the SMPL button to start counting pieces Place a certain number of items to be weighed on the weighing surface You must know the exact number Enter this number using the numeric keypad Press the SMPL button agai...

Page 9: ...play shows OK The minimum value is set and the maximum value is zero The display shows OK as long as the weight is lower than the set minimum value When the applied weight exceeds the minimum value the display shows HIGH The minimum value is zero and the maximum value is set The display shows LOW as long as the applied weight is lower than the set maximum value When the applied weight exceeds the ...

Page 10: ...not upgrade able To clear the totaliser press the MC button The M sum function is enabled only if the display shows STABLE 6 7 2 Automatic totaliser The scale can be set so that the weight values on the display are automatically added to the values in the totalis er For this purpose parameter P6 Ato must be enabled setting Au on For more details see parameter settings When the automatic totaliser ...

Page 11: ...E button moves to the next lower setting Press the ZERO button again to save your entries Press the G N button to exit the menu without saving Please note that some functions are only reserved for use by authorised technicians according to the overview below PARA METER SUB PARA METER DISPLAY SETTING P0 CAL External calibration Reserved for use by authorised technicians only P1 LCA Linearity calibr...

Page 12: ...ptions Auto on off Auto Backlight is enabled when the weighing surface is loaded on Backlight is permanently enabled of Backlight is permanently disabled P12 bP BEEP Audible signal setting for checkweighing 0 Audible signal is disabled 1 Audible signal between two values is enabled 2 Audible signal beyond two values is enabled P13 ti Time Year date and time setting Navigate within the digits with ...

Page 13: ...tch on zero exceeds the permissible value typically 4 of the maximum weighing range when the scale is switched on or when the ZERO button is pressed The weighing platform has already been loaded when the scale has been switched on Weighing platform overload when the scale is set to zero Improper calibration of the scale Damaged load cell Damaged electronics Err 5 Keypad fault Improper use of the s...

Page 14: ...idence is provided that it has failed within 1 year from the date of sale proof of purchase is required due to lack of workmanship or defective material All moving parts such as batteries cables etc are excluded The use of accessories other than those approved by ADE especially batteries will void the warranty This warranty does not cover external normal wear and tear or damage caused by accident ...

Page 15: ... adapter Calibration With external weight Display 6 digit LCD digital displays 52 mm digit height Housing ABS plastic housing stainless steel weighing platform Weighing platform 365 x 235 mm Housing dimensions WxDxH 365 x 365 x 135 mm Net weight 5 1 kg Applications Multi purpose scale with simple piece counting function Functions Weighing piece counting totaliser freely programmable minimum and ma...

Page 16: ...rer This product has been manufactured in accordance with the harmonised European standards They conform to the regulations of the EC directives listed below EMC Directive 2014 30 EU Low voltage directive 2014 35 EU RoHS Directive 2011 65 EC in the currently valid versions This declaration will lose its validity if any modification is made to the scale without our consent Hamburg May 2021 ADE Germ...

Page 17: ...ZW60 210531 Rev006 UM en 17 ...

Page 18: ...18 ZW60 210531 Rev006 UM en ...

Page 19: ...ZW60 210531 Rev006 UM en 19 ...

Page 20: ...20 ZW60 210531 Rev006 UM en Händler ...

Reviews: