ADE M50010 Operating Manual Download Page 8

7  

050100-Rev000-M50010 

 

Warranty – Liability 

 
ADE will repair or replace this product within a period of 2 years from date of delivery applying to 
defects occurred due to poor material or workmanship (presentation of invoice is necessary). All 
moveable parts – batteries, cables, mains units, rechargeable batteries etc. – are excluded. Warranty 
does not include natural wear, damages caused by incorrect or negligent handling, overuse or 
unsuitable or improper storage. The cost of transport will be borne by the customer should the 
equipment be located anywhere other then the customer’s premises. In the event of transport 
damage, claims under warranty can be accepted subject to using the complete original packaging and 
the equipment secured the way it was packed and secured originally. All the packaging should 
therefore be retained.  
 
Any warranty claim will be rejected if the equipment is opened by persons not authorized expressively 
by ADE to do so. 
 
Customers abroad are kindly requested to contact their local dealer for any warranty claim, customer 
service and spare parts. 
 
 

Re-approval 

 

For re-approval of the scale as per the national directives governing the standards for non automatic 
scales as well as for medical devices please make sure to contact only authorized companies or 
persons. On the CE sign you are finding the number of the notified body (0110) and the year of the 
first approval of the scale. A re-approval becomes necessary  
 

IF the approval seal has been damaged 

AFTER repair of an approved scale 

-  OR after expiry of the validity of the first approval which is nationally regulated. For further 

information please contact your Weight & Measure Institute. 

 

Technical Data 

 

Display: 

Easy to read 25 cm LCD Display  

Housing of Display: 

 

Robust plastic housing 

Power supply:   

 

Mains & rechargeable batteries (power-pack) 

Function keys:   

 

20 keys (see chapter components & features) 

Interface: 

RS 232 with automatic Baud rate selection  

AD sampling rate: 

Triple selection 

Zero setting: 

Automatic 

Weighing station: 
Max. Capacity: 

300 kg / 660 lbs 

Graduation: 

100 g / 0.2 lb 

Access to ramp:                         44 mm 
Dimensions: 

915 x 55 x 800 mm 

Total weight:                               22 kg 
Working Temperature: 

10 to +40 degrees Celsius 

 

Supplier: 

ADE  GmbH  & Co. 

 

Hammer Steindamm 27 – 29 

 22089 

Hamburg 

Germany 

Summary of Contents for M50010

Page 1: ...Operating Manual Electronic Wheelchair Scale class III approved M50010 ADE GmbH Co Hammer Steindamm 27 29 22089 Hamburg GERMANY 49 40 432776 0 Fax 49 40 432776 10 E mail info ade hamburg de...

Page 2: ...d scales are imperative 4 Connecting additional equipment 4 Quality check 4 EC type approval 4 Use of the scale 5 Weighing 5 Body Mass Index BMI 5 Evaluation of the Body Mass Index 5 Tare functions 5...

Page 3: ...y to be tared HOLD To fix the weighing result BMI To evaluate the BMI Body Mass Index SEMI AUTO TARE To tare a value automatically UNITS To change the weighing unit CLEAR Clear indication ENTER Confir...

Page 4: ...Manual including Certificate of Conformity Attention Carefully check identity of the serial numbers on the platform and the indicator which is mandatory for medical use of the scale Power Supply of t...

Page 5: ...pean Directive 93 42 EEC for medical devices and declares the conformity as per this Directive Due to the certification as per ISO 9001 2000 the high standards for Research Development Manufacturing S...

Page 6: ...BMI is calculated and displayed Evaluation of the Body Mass Index BMI below 18 The patient is not showing enough weight Control nutrition to put on weight BMI between 18 and 20 The patient is slightly...

Page 7: ...Display indication Lo Recharge the power pack by connecting the mains adapter to the display Display indication ErrL Check correct positioning of the scale see chapter installation use of scale and m...

Page 8: ...or any warranty claim customer service and spare parts Re approval For re approval of the scale as per the national directives governing the standards for non automatic scales as well as for medical d...

Page 9: ...i folgende direktiver 90 384 EEC om ikke automatiske vekter 93 42 EEC om medisinske proukter og den europeiske standarden DIN EN 45501 FIN on tyyppihyv ksynt todistuksessa kuvatun raken nemallin muka...

Page 10: ...9 050100 Rev000 M50010...

Page 11: ...050100 Rev000 M50010 10...

Page 12: ...11 050100 Rev000 M50010...

Reviews: