ADE M403660 Operating Manual Download Page 8

 

M403660-211129-Rev006-UM-e 

HOLD function 

The Hold function is being used if you like to hold the results at the display after the weight/load has 
been removed from the scale. 

Press 

HOLD

 key while scale is under load. 

“HOLD” is being displayed at the screen. 

The weight remains saved in the display after unloading the scale. 

For deactivation of the Hold function press again the 

HOLD

 key. 

 

BMI (Body Mass Index) 

The Body Mass Index is the ratio between height and weight squared. The BMI is accepted world wide 
– also by WHO (World Health Organization) - helping to evaluate the state of nutrition and with that 
value also the state of health of a person. The result is a tolerance value. 

Start the scale by entering the ON/OFF button. The scale is automatically being set to zero. 

Help the patient into the chair. 

Take care that the feet are being rested on the footrest. 

Wait until the weight is being displayed in a stable condition and 



´ appears on the screen. 

Press the 

BMI

 key shortly. 

The scale starts automatically with the last input. Use the arrow buttons to enter the height of 
the patient. 

 

 

 

 Confirm the height with the enter button 

 .

 

The BMI is now being displayed . 

To correct the given height figures press the BMI button once again and the display returns to 
the height mode. 

To get back into normal weighing mode and leave the BMI modus simply step off the platform. 

 

Evaluation of the Body Mass Index 

Compare the determined value which corresponds to those being used by the WHO. 

BMI below 18,5 

  The patient is under the regular standard and does not got enough weight. An increase of 

weight is recommended. Please consult a professional. 

BMI between 18,5 and 24,9 

  The patient got a normal weight. If he feels well there is no need for a change. 

BMI between 25 and 30 

  The patient is slightly overweighed to pre-obese. A reduction of weight is indicated or, is 

necessary if the state of health is already affected (e.g. diabetes, high end blood pressure, 
heart diseases). 

BMI over 30 

  Reduction of weight is imperative. To visit a doctor is highly recommended. 

 

Connecting additional devices 

Connection of printer, PC or remote-display will be done with the RS-232 interface. For connection of 
additional devices kindly ask your local representative or authorized ADE dealer for further instructions. 

 

Summary of Contents for M403660

Page 1: ...Operating Manual International Range Electronic Chair Scales M403660 M403660 211129 Rev006 UM e...

Page 2: ...scription 4 Key pad 5 Operation 5 Positioning of patient 5 How to change the unit 6 Tare function 6 Weighing with preset tare values 6 HOLD function 7 BMI Body Mass Index 7 Evaluation of the Body Mass...

Page 3: ...uctions in this operating manual the country specific installation standards as well as the applicable safety conditions and accident prevention regulations in all aspects Operate the scale only with...

Page 4: ...rgeable batteries Use the AC adapter to load the rechargeable batteries The imprinted voltage value at the mains adapter must match the local mains voltage When the battery is being charged for the fi...

Page 5: ...thin the zero level Standstill status indicator 14 The scale is at a standstill meaning the weight is stable and no movement is on the platform This is a mandatory precondition for functions such as r...

Page 6: ...witch between the numbers downwards In BMI mode use this key to switch between the numbers upwards Enter button to confirm the value Operation Positioning of patient Please ensure for security reasons...

Page 7: ...hing on to get proper result Tare function The tare function allows ignoring a fixed weight e g clothes that will be deducted after each weighing procedure Proceed as follows Press the start key with...

Page 8: ...w buttons to enter the height of the patient Confirm the height with the enter button The BMI is now being displayed To correct the given height figures press the BMI button once again and the display...

Page 9: ...thorized personnel Weight reading exceeds load limit Reduce load on scale until weight value can be displayed Weight reading below load limit Service by authorized personnel required Configuration or...

Page 10: ...elivery applying to defects occurred due to poor material or workmanship presentation of invoice is necessary All moveable parts batteries cables mains units rechargeable batteries etc are excluded Wa...

Page 11: ...dapter AC Adapter 6 9VDC 500mA Central negative 4xAA NIMH rechargeable batteries pack Display 6 digit 7 segment 1 25mm LCD with 16 annunciators and blue backlight Working temperature 10 C to 40 C Stor...

Page 12: ...ermany 49 40 432 776 0 49 40 432 776 10 info ade germany de www ade germany de Declaration of conformity by the manufacturer These scales have been manufactured in accordance with the harmonised Europ...

Page 13: ...M403660 211129 Rev006 UM e 12...

Page 14: ...13 M403660 211129 Rev006 UM e...

Page 15: ...M403660 211129 Rev006 UM e 14...

Page 16: ...15 M403660 211129 Rev006 UM e authorised dealer...

Reviews: