Introduction 

 

This symbol means: "Consult operating instructions". To achieve accurate results, read 
the instructions for use carefully before use and follow all instructions provided therein. 
Keep the instructions for use for future reference. 

Your ADE electronic chair-scale is a quality, sturdy and durable product manufactured in accordance 
with national regulations in Germany.  

ADE  instruction  manuals  have  been  prepared  to  provide  the  user  with  all  the  necessary  knowledge 
about the safe use of ADE scales and their related accessory equipment.  

For further questions about how to use the products or about this or other service manuals, feel free to 
contact your local ADE representative or visit our web page at www.ade-hamburg.de. 

In order to achieve the best possible results kindly read and follow the operation manual in all respects. 

Check carton contents 

Chair Scale - assembled 

Mains adapter 

Bag for accessoiries 

Operating manual  

Safety 

The ADE-display unit corresponds to the latest state of the art technology and complies with standard 
regulations and directives. Kindly follow the safety instructions in this operating manual, the country-
specific installation standards as well as the applicable safety conditions and accident prevention 
regulations in all aspects.  

  Operate the scale only with the original ADE mains adapter.

 

  Always connect the mains adapter to the scale 

BEFORE

 connecting it to the electrical outlet. 

  Disconnect from the electrical outlet 

BEFORE

 disconnecting the adapter from the scale.

 

  In case the mains adapter became wet or show visible damages the scale can no longer be 

operated by using this mains adapter. In this case please contact your local dealer or service 
partner. 

  The voltage and power supply as mentioned on the type plate must match the mains voltage 

and power type at the place of use. 

  When using the scale with a mains unit ensure that the supply cable is routed in such a way as 

to exclude any type of potential trip hazard. 

  Remove the mains plug before cleaning the unit. 

  Do not operate the unit in hazardous or unstable conditions. 

  Set up the unit as far away as possible from equipment that generates electromagnetic or 

other interference. Portable and mobile HF-communication systems may influence electronic 
medical devices. 

  All actions and operations described in this operation manual may only be carried out by 

professional personnel authorized by ADE or official appointed dealers. 

 

 

 

 

 

 

Summary of Contents for M403660

Page 1: ...Operating Manual International Range Electronic Chair Scales M403660 M403660 211129 Rev006 UM e...

Page 2: ...scription 4 Key pad 5 Operation 5 Positioning of patient 5 How to change the unit 6 Tare function 6 Weighing with preset tare values 6 HOLD function 7 BMI Body Mass Index 7 Evaluation of the Body Mass...

Page 3: ...uctions in this operating manual the country specific installation standards as well as the applicable safety conditions and accident prevention regulations in all aspects Operate the scale only with...

Page 4: ...rgeable batteries Use the AC adapter to load the rechargeable batteries The imprinted voltage value at the mains adapter must match the local mains voltage When the battery is being charged for the fi...

Page 5: ...thin the zero level Standstill status indicator 14 The scale is at a standstill meaning the weight is stable and no movement is on the platform This is a mandatory precondition for functions such as r...

Page 6: ...witch between the numbers downwards In BMI mode use this key to switch between the numbers upwards Enter button to confirm the value Operation Positioning of patient Please ensure for security reasons...

Page 7: ...hing on to get proper result Tare function The tare function allows ignoring a fixed weight e g clothes that will be deducted after each weighing procedure Proceed as follows Press the start key with...

Page 8: ...w buttons to enter the height of the patient Confirm the height with the enter button The BMI is now being displayed To correct the given height figures press the BMI button once again and the display...

Page 9: ...thorized personnel Weight reading exceeds load limit Reduce load on scale until weight value can be displayed Weight reading below load limit Service by authorized personnel required Configuration or...

Page 10: ...elivery applying to defects occurred due to poor material or workmanship presentation of invoice is necessary All moveable parts batteries cables mains units rechargeable batteries etc are excluded Wa...

Page 11: ...dapter AC Adapter 6 9VDC 500mA Central negative 4xAA NIMH rechargeable batteries pack Display 6 digit 7 segment 1 25mm LCD with 16 annunciators and blue backlight Working temperature 10 C to 40 C Stor...

Page 12: ...ermany 49 40 432 776 0 49 40 432 776 10 info ade germany de www ade germany de Declaration of conformity by the manufacturer These scales have been manufactured in accordance with the harmonised Europ...

Page 13: ...M403660 211129 Rev006 UM e 12...

Page 14: ...13 M403660 211129 Rev006 UM e...

Page 15: ...M403660 211129 Rev006 UM e 14...

Page 16: ...15 M403660 211129 Rev006 UM e authorised dealer...

Reviews: