Any warranty claim will be rejected if the equipment is opened by persons not authorized expressively 
by ADE to do so. 
 
Customers abroad are kindly requested to contact their local dealer for any warranty claim, customer 
service and spare parts. 
 

Re-approval 

 

For re-approval of the scale as per the national directives governing the standards for non automatic 
scales as well as for medical devices please make sure to contact only authorized companies or 
persons. On the CE sign you are finding the number of the notified body (0110) and the year of the 
first approval of the scale. A re-approval becomes necessary  
 

IF the approval seal has been damaged 

AFTER repair of an approved scale 

-  OR after expiry of the validity of the first approval which is nationally regulated. For further 

information please contact your Weight & Measure Institute. 

 

Technical data 

 

 

Display: 

easy to read 25 cm LCD Display  

Housing of Display: 

 

robust plastic housing 

Power supply:   

 

Mains & rechargeable batteries  

Function keys:   

 

20 keys (see chapter components & features) 

Interface: 

RS 232 with automatic Baud rate selection 

AD sampling rate: 

triple selection 

Zero setting: 

automatic 

Weighing station: 
Max. Capacity: 

250 kg / 550 lbs 

Graduation: 

100 g / 0,2 lb 

Dimensions (WxHxD): 

570 x 935 x 1055 mm 

Working Temperature: 

10 to +40 degrees Celsius 

Total weight of scale: 

abt. 28 kg 

 

 

Supplier: 

ADE GmbH  & Co. 

 

Hammer Steindamm 27 – 29 

 22089 

Hamburg 

Germany 

Summary of Contents for M40010

Page 1: ...Operating Manual Electronic Chair Scale class III approved M40010 ADE GmbH Co Hammer Steindamm 27 29 D 22089 Hamburg Germany 49 40 432776 0 Fax 49 40 432776 10 E mail info ade hamburg de...

Page 2: ...re approved scales are imperative 3 Connecting additional equipment 3 Quality check 4 EC type approval 4 Use of the scale 4 Weighing 4 Body Mass Index BMI 5 Evaluation of the Body Mass Index 5 Tare fu...

Page 3: ...e tared HOLD To fix the weighing result BMI To evaluate the BMI Body Mess Index SEMI AUTO TARE To tare a value automatically UNITS To change the weighing unit kg lbs CLEAR Clear indication ENTER Confi...

Page 4: ...12V 300mA and rechargeable batteries power pack The battery pack is already installed in the display Charge the power pack by using the mains adapter and connect the jack firmly to the display Comple...

Page 5: ...with class III sign are calibrated in accordance with the high precision standards laid down in EC Directive 90 384 EEC Products carrying this symbol meet the requirements of Directive for non automat...

Page 6: ...abetes high end blood pressure heart diseases BMI over 30 Reduction of weight is imperative Also to visit a doctor is highly recommended Tare functions The SEMI AUTO TARE key is used for taring object...

Page 7: ...shows visible damages If mains adapter is not working properly After long storage in humid places In those cases contact your local dealer or service partner Storage and Transport Keep all original pa...

Page 8: ...approval becomes necessary IF the approval seal has been damaged AFTER repair of an approved scale OR after expiry of the validity of the first approval which is nationally regulated For further info...

Page 9: ...i folgende direktiver 90 384 EEC om ikke automatiske vekter 93 42 EEC om medisinske proukter og den europeiske standarden DIN EN 45501 FIN on tyyppihyv ksynt todistuksessa kuvatun raken nemallin muka...

Page 10: ...9 050100 Rev000 M40010...

Page 11: ...050100 Rev000 M40010 10...

Page 12: ...11 050100 Rev000 M40010...

Reviews: