background image

 

Page 8 of 16 

IRIS Touch 

 Quick Installation & Maintenance Guide Version 1.0 

 

 

Reference 

ground pins 

Pin inputs 

 

GSM SIM card (IRIS Touch 200 & 240) 

6.4.

DO NOT FIT the SIM card until after you have performed the GPRS Network Scan detailed in the 

Section 6.8 

“Configuration”

 you will be prompted when to insert the SIM card. 

 

Dial capture 

6.5.

Dial capture enabled systems

: Connect the dial port screw terminals with the alarm panel dialler telecoms 

line connections.  

Note: Polarity is not important in this instance.  

Fit the supplied 18K sense resistor in parallel with the dialler output of the alarm panel, at the alarm panel 
end of the cable.  

Note: This resistor enables the dialler to detect cable faults and/or tampers and must be fitted at the alarm 
panel end of the cable to function correctly.

 

 

PIN Inputs 

6.6.

The IRIS Touch dialler has 4 pin inputs

 

that can be used to generate alarm messages, if you require more 

than 4 pin inputs then you can fit the IRIS Touch 

 expansion board (ordered separately). These can be: 

 

Text messages via SMS 

(GSM

). 

 

SIA, Contact ID and Fast Format alarm messages over IP to the monitoring centre. 

Note: These pin alarm inputs can also be used when the dialler is directly connected to an alarm panel 
via the serial or RS485 connections. 

Via Open/Close Contact Source 

Each pin input is designed to be connected in a loop via 
an open/close contact source from an alarm panel, or 
other device, to a reference ground pin available on the 
IRIS dialler, as shown opposite. 

Opening the contact (i.e. loop is open circuit) generates 
an alarm signal. Closing the contact generates the 
equivalent restore signal. 

Via Sense Resistors 

It is also possible to link the contacts to the IRIS dialler via 
sense resistors so that an open or short circuit tamper on 
the loop can be detected and the monitoring centre 
alerted. In this case, the connections should be made as 
shown opposite.  

Note:

 For this feature to work correctly it is essential that 

the resistors are connected at the contact end of the loop 
and not the dialler end. The monitoring centre must also 
enable the monitoring of this facility on the dialler within 
the IRIS Secure Apps receiving system. 

 

Switch on and test 

6.7.

To confirm power is applied, look for the indicator SYS LED is flashing yellow 

 on the IRIS Touch dialler 

board. 

 

 

4K7 Resistor 

15K Resistor 

 

Reference 

ground pins 

Pin inputs 

Summary of Contents for Iris Touch 2 Series

Page 1: ...IRIS Touch Quick Installation Maintenance Guide Version 1 0...

Page 2: ...Page 2 of 16 IRIS Touch Quick Installation Maintenance Guide Version 1 0...

Page 3: ...ouch 7 Mounting 7 6 1 Power 7 6 2 Connections 7 6 3 GSM SIM card IRIS Touch 200 240 8 6 4 Dial Capture 8 6 5 PIN Inputs 8 6 6 Switch on and test 8 6 7 Configuration 9 6 8 Panel Configuration 10 6 9 Te...

Page 4: ...or configuration local alerts and allows diagnostic and tests to be performed by the engineer Polling and alarm over communication paths of Ethernet and or GPRS 3G 4G and CDMA on request to the monito...

Page 5: ...Yellow flashing Not currently configured or indicating that there are some current faults outstanding Yellow constant Communicating and no current faults flickers on every poll Micro USB Front tamper...

Page 6: ...Ethernet LAN network details are required in order to connect the IRIS Touch The following information should be obtained from the customer Fixed IP address or DHCP If using DHCP then the following i...

Page 7: ...TO THE DIALLER UNTIL INDICATED Connections 6 3 Connect cables to the PCB for your system as shown on in Section 4 Board Configuration Ethernet enabled systems IRIS Touch 220 240 Ethernet socket ETH1...

Page 8: ...ges over IP to the monitoring centre Note These pin alarm inputs can also be used when the dialler is directly connected to an alarm panel via the serial or RS485 connections Via Open Close Contact So...

Page 9: ...croll bar on right till you see option for Default All 3 Enter the Default All and confirm the default this will cause the dialler to reboot and will now be defaulted Configuration via touch screen IR...

Page 10: ...toring centre IP address e g 192 168 0 34 would become 192168000034 Acoount Number 4 6 digit account number allocated by the monitoring centre Note If the Alarm Override mode is selected the IRIS Touc...

Page 11: ...and can perform the following checks Confirm current status 7 1 The IRIS Touch will indicate Status ok If the current dialler setup is all working correctly and if the status is showing Status Troubl...

Page 12: ...his will test all configured communication paths Please refer to the IRIS Touch Engineer Manual for more details available from http www chironsc com downloads_security html Test alarm panel alarms an...

Page 13: ...rface to alarm panel RS485 RS232 TTL RS232 PIN Inputs interface to alarm panel Maximum input voltage range 0V to 24V Input low alarm threshold 1V Input high restore threshold 2V Internal pull up imped...

Page 14: ...s Dial capture interface SELV suitable for connection to the TNV interface of single line telecommunications equipment such as telephones fax machines etc Power Interface SELV for connection to a DC s...

Page 15: ...IRIS Touch Quick Installation Maintenance Guide Version 1 0 Page 15 of 16...

Page 16: ...quiries 41 435 080 870 Email sales chironsc com www chironsc com CHIRON SECURITY COMMUNICATIONS AG BAARERSTRASSE 19 6300 ZUG SWITZERLAND The information contained is supplied without liability for any...

Reviews: