 Quick Installation & Maintenance Guide Version 1.0 

 

 

Safety 

Care should be taken when connecting telecommunications equipment to ensure only like interfaces are 
connected to avoid safety hazards. 

SELV: 

SELV (Safety Extra-Low Voltage) is defined as a secondary circuit which is so designed 
and protected that under normal and single fault conditions the voltage between any 
two accessible parts does not exceed a safe value (42.4V peak or 60V dc maximum) 

The interfaces on the IRIS Touch have the following safety classifications: 

 

Dial capture interface: SELV suitable for connection to the TNV interface of single line 
telecommunications equipment such as telephones, fax machines, etc. 

 

Power Interface: SELV for connection to a DC supply 

 

Inputs: SELV for connection to alarm output pin. 

Conformance

 

European Directives

 

The IRIS Touch complies with the following European Directives: 

 

1999/5/EC (Radio & Telecoms Terminal Equipment Directive) 

 

2006/95/EC (Low Voltage Directive) 

 

2004/108/EC (Electromagnetic Compatibility Directive) 

 
EN50131, EN50136 (VdS Certified)

 

The dialler is compliant to the requirements of European Standards: 

EN50131-1: 2006 & EN50131-10: 2014 
EN50136-1: 2012 & EN50136-2: 2013 
Security Grade 4 ATS-SP6 (IRIS Touch 200, 220 and 240), ATS-DP4 (IRIS Touch 240) / Environmental Class II 

 

 

 

Summary of Contents for Iris Touch 2 Series

Page 1: ...IRIS Touch Quick Installation Maintenance Guide Version 1 0...

Page 2: ...Page 2 of 16 IRIS Touch Quick Installation Maintenance Guide Version 1 0...

Page 3: ...ouch 7 Mounting 7 6 1 Power 7 6 2 Connections 7 6 3 GSM SIM card IRIS Touch 200 240 8 6 4 Dial Capture 8 6 5 PIN Inputs 8 6 6 Switch on and test 8 6 7 Configuration 9 6 8 Panel Configuration 10 6 9 Te...

Page 4: ...or configuration local alerts and allows diagnostic and tests to be performed by the engineer Polling and alarm over communication paths of Ethernet and or GPRS 3G 4G and CDMA on request to the monito...

Page 5: ...Yellow flashing Not currently configured or indicating that there are some current faults outstanding Yellow constant Communicating and no current faults flickers on every poll Micro USB Front tamper...

Page 6: ...Ethernet LAN network details are required in order to connect the IRIS Touch The following information should be obtained from the customer Fixed IP address or DHCP If using DHCP then the following i...

Page 7: ...TO THE DIALLER UNTIL INDICATED Connections 6 3 Connect cables to the PCB for your system as shown on in Section 4 Board Configuration Ethernet enabled systems IRIS Touch 220 240 Ethernet socket ETH1...

Page 8: ...ges over IP to the monitoring centre Note These pin alarm inputs can also be used when the dialler is directly connected to an alarm panel via the serial or RS485 connections Via Open Close Contact So...

Page 9: ...croll bar on right till you see option for Default All 3 Enter the Default All and confirm the default this will cause the dialler to reboot and will now be defaulted Configuration via touch screen IR...

Page 10: ...toring centre IP address e g 192 168 0 34 would become 192168000034 Acoount Number 4 6 digit account number allocated by the monitoring centre Note If the Alarm Override mode is selected the IRIS Touc...

Page 11: ...and can perform the following checks Confirm current status 7 1 The IRIS Touch will indicate Status ok If the current dialler setup is all working correctly and if the status is showing Status Troubl...

Page 12: ...his will test all configured communication paths Please refer to the IRIS Touch Engineer Manual for more details available from http www chironsc com downloads_security html Test alarm panel alarms an...

Page 13: ...rface to alarm panel RS485 RS232 TTL RS232 PIN Inputs interface to alarm panel Maximum input voltage range 0V to 24V Input low alarm threshold 1V Input high restore threshold 2V Internal pull up imped...

Page 14: ...s Dial capture interface SELV suitable for connection to the TNV interface of single line telecommunications equipment such as telephones fax machines etc Power Interface SELV for connection to a DC s...

Page 15: ...IRIS Touch Quick Installation Maintenance Guide Version 1 0 Page 15 of 16...

Page 16: ...quiries 41 435 080 870 Email sales chironsc com www chironsc com CHIRON SECURITY COMMUNICATIONS AG BAARERSTRASSE 19 6300 ZUG SWITZERLAND The information contained is supplied without liability for any...

Reviews: