Section 2.2 - Installing Your SR-60 into a Rack
A.
B.
The chassis package includes two rail assemblies in the rack mounting kit. Each assembly consists of
two sections: an inner fixed chassis rail that secures directly to the server chassis and an outer fixed
rack rail that secures directly to the rack itself.
Press the lever to
extend the outer rails.
Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the
floor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip
over and cause severe injury to the technicians and damage to the device.
This section provides information on installing the SR-60 chassis into a rack unit with the quick-release
rails provided.
C.
Repeat step A to mount
all four corners.
Hang the hooks of the rails
into rack holes. Screw the
rails in if necessary.
Make sure the ball shuttle is
at the very front.
Inner and outer chassis rails are shipped together, before continuing please seperate outer rail from
inner rail.