page 16
ADDAC SYSTEM
This setting is shared by all 4 Voices.
Default value is 40 milliseconds (Button 3).
Image 2
Image 1
INTUITIVE MENU
GATE L.
- Gate Length Operation
- Buttons 1 to 11 and 12
Ex. III
BUTTON 1
10 ms
GATE LENGTH
BUTTON 2
20 ms
BUTTON 3
40 ms
BUTTON 4
80 ms
BUTTON 5
160 ms
BUTTON 6
320 ms
BUTTON 7
640 ms
BUTTON 8
1280 ms
BUTTON 9
2560 ms
BUTTON 10
5120 ms
BUTTON 11
10240 ms
The Minimum value for this setting is 10 milliseconds (Button 1) the maximum is
10240 miliseconds (Button 11).
Time intervals increase multiplying by 2, meaning the next button is twice the size
of its previous one: Button 1=10 Milliseconds ; 2=20; 3=40; 4=80... and so on.
It can also be calculated with the formula:
Milliseconds = 10*2^(ButtonX-1)
Button 12 is used for a GATE OFF CONDITION before Quantizing a new note
(described below).
So let’s imagine we have already pressed the
GATE L.
Button for aprox. 1 second
and entered in its Menu Window, the Menu Buttons already changed to the configu-
ration shown in image 1, displaying the default setting for Gate Length or Button 3.
If it’s the User’s wish to change the Gate Length to any
other size he’ll need to press the desired length button
twice. Let’s assume Button 7 (640 miliseconds)
Once Button 7 is lit (image 2) pressing it once again
confirms the new setting and Exits the Menu Window.
GATE OFF CONDITION
Button 12 acts as a Toggle (Lit = On, Unlit = Off).
It limits the quantization process to happen only when
the gate Out is Off.
For ex. Imagine the User had already pressed Button 12
(image 2) setting the Gate Length to be 10 seconds.
As soon as the module quantizes a new note it will set
the Gate Out to +5v and hold it there for the pre-defined
time of 10 seconds.
With Button 12 Lit (Condition On) it will ignore any input
and will not quantize any note until the 10 seconds pass
and the Gate set to 0v.
ADDAC207 INTUITIVE QUANTIZER
USER’S GUIDE
April.2021
Revision.05
Summary of Contents for ADDAC207
Page 1: ......